Catalogue / Substation & line O&M
Substation O&M with 24x7 shift operation, Eco 9 seriesSample
by Prakashsys Infra Services (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Prakashsys Infra Services (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Prakashsys Eco 9 substation O&M with 24x7 shift operation, offered in 4 voltage level options from 11 kV to 132 kV. Highlights: insulator and joint inspection, oil leak and silica gel checks and permit-to-work and lockout-tagout. Suited to state utility outsourcing, industrial captive substations and renewable pooling substations. Delivered in line with CEA (Measures relating to Safety) Regulations, CEA (Grid Standards) Regulations and IS 10028 (Transformer Installation). Mobilisation Mobilisation in 2-3 weeks; serves All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Prakashsys
- Model
- PRA-0A2 series
- Listing type
- Service
- Unit
- month
- Minimum order
- 1 month
- Lead time
- Mobilisation in 2-3 weeks
- Warranty
- Service credits for avoidable outages
- Standards
- CEA (Measures relating to Safety) Regulations, CEA (Grid Standards) Regulations, IS 10028 (Transformer Installation)
- Delivers to
- All India and export (SAARC, Middle East, Africa)
- GST rate
- 18 %
- Country of origin
- India
- Delivery terms
- Site mobilisation as per work order
- Returns
- Re-work of defective scope at no cost
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Voltage level11 kVPRA-0A2-01 | Voltage level: 11 kV | 1 month · Mobilisation in 2-3 weeks | for verified buyers |
| Voltage level33 kVPRA-0A2-02 | Voltage level: 33 kV | 1 month · Mobilisation in 2-3 weeks | for verified buyers |
| Voltage level66 kVPRA-0A2-03 | Voltage level: 66 kV | 1 month · Baseline condition audit first | for verified buyers |
| Voltage level132 kVPRA-0A2-04 | Voltage level: 132 kV | 1 month · Baseline condition audit first | for verified buyers |
Specifications
| Voltage level | 11 kV to 132 kV (see variants) |
|---|---|
| Scope | Maintenance only |
| Shift pattern | 3 shifts, 24x7made to order: General shift plus on-call |
| Manpower | Engineer plus 6 operatorsmade to order: Two engineers plus 12 staff |
| Line patrolling | Quarterly drone patrol |
| Testing | Annual relay and CT/PT test |
| Statutory records | Log books, permits, shutdown register |
| Spares | Critical spares by owner |
| Response time | 4 hours |
| Reporting | Real-time dashboardsmade to order: Monthly fault and maintenance report |
| Term | 3 years |