Catalogue / Substation & line O&M
Switchyard preventive maintenance, Smart seriesSample
by Prakashsys Infra Services (Sample) · verified by BARREL
Price on quote
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Prakashsys Infra Services (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
The Smart service of switchyard preventive maintenance by Prakashsys covers 3 voltage level options (66 kV to 220 kV). Design: fault analysis within 24 hours, permit-to-work and lockout-tagout and oil leak and silica gel checks. Typically used for railway and metro sub-stations, state utility outsourcing and industrial captive substations. Delivered in line with CEA (Measures relating to Safety) Regulations, CEA (Grid Standards) Regulations and IS 10028 (Transformer Installation). Mobilisation Mobilisation in 2-3 weeks; serves All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Prakashsys
- Model
- PRA-8E7 series
- Listing type
- Service
- Unit
- month
- Minimum order
- 1 month
- Lead time
- Mobilisation in 2-3 weeks
- Warranty
- Service credits for avoidable outages
- Standards
- CEA (Measures relating to Safety) Regulations, CEA (Grid Standards) Regulations, IS 10028 (Transformer Installation)
- Delivers to
- All India and export (SAARC, Middle East, Africa)
- GST rate
- 18 %
- Country of origin
- India
- Delivery terms
- Site mobilisation as per work order
- Returns
- Re-work of defective scope at no cost
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Voltage level66 kVPRA-8E7-01 | Voltage level: 66 kV | 1 month · Mobilisation in 2-3 weeks | on quote |
| Voltage level132 kVPRA-8E7-02 | Voltage level: 132 kV | 1 month · Mobilisation in 2-3 weeks | on quote |
| Voltage level220 kVPRA-8E7-03 | Voltage level: 220 kV | 1 month · Mobilisation in 2-3 weeks | on quote |
Specifications
| Voltage level | 66 kV to 220 kV (see variants) |
|---|---|
| Scope | Operation, maintenance and statutory compliancemade to order: Operation and maintenance / Maintenance only |
| Shift pattern | 3 shifts, 24x7 |
| Manpower | Two engineers plus 12 staffmade to order: Engineer plus 6 operators |
| Line patrolling | Monthly foot patrol |
| Testing | Thermography twice a year |
| Statutory records | CEIG renewal support |
| Spares | Consumables includedmade to order: Critical spares by owner |
| Response time | 4 hoursmade to order: 2 hours for trip |
| Reporting | Real-time dashboardsmade to order: Monthly fault and maintenance report |
| Term | 3 years |