Prithvicore Prime SF6 live tank circuit breaker, offered in 6 system voltage options from 36 kV to 800 kV. Design: point-on-wave controller option, low SF6 leakage < 0.5% per year and density monitor with two stage alarm. Used by grid substations, generator bays and transmission lines. Designed and tested to IEC 62271-100, IS 13118 and IEC 62271-1. Lead time 24-30 weeks; delivers to East & North-East India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Prithvicore
- Model
- PRI-786 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 10 nos
- Lead time
- 24-30 weeks
- Warranty
- 24 months from commissioning
- Standards
- IEC 62271-100, IS 13118, IEC 62271-1
- Delivers to
- East & North-East India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Wooden crate, seaworthy
- Delivery terms
- Door delivery in metro cities
- Returns
- No returns on made-to-order items
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| System voltage36 kVPRI-786-01 | System voltage: 36 kV | 10 nos · 24-30 weeks | for verified buyers |
| System voltage72.5 kVPRI-786-02 | System voltage: 72.5 kV | 10 nos · 24-30 weeks | for verified buyers |
| System voltage145 kVPRI-786-03 | System voltage: 145 kV | 10 nos · 24-30 weeks | for verified buyers |
| System voltage245 kVPRI-786-04 | System voltage: 245 kV | 10 nos · 24-30 weeks | for verified buyers |
| System voltage420 kVPRI-786-05 | System voltage: 420 kV | 10 nos · 24-30 weeks | for verified buyers |
| System voltage800 kVPRI-786-06 | System voltage: 800 kV | 10 nos · 24-30 weeks | for verified buyers |
Specifications
| System voltage | 36 kV to 800 kV (see variants) |
|---|---|
| Rated current | 4000 A |
| Breaking current | 40 kA |
| Operating mechanism | Hydraulic springmade to order: Spring-spring |
| Operation | 3-polemade to order: Single-pole |
| Interrupter | Two breaks |
| SF6 pressure | 0.6 MPa abs |
| Duty cycle | O-0.3s-CO-3min-CO |
| Close time | < 60 msmade to order: < 100 ms |
| Insulator | Porcelainmade to order: Composite |
| Auxiliary supply | 110 V DC |
| Creepage | 25 mm/kVmade to order: 31 mm/kV |
| Mechanical endurance | M2 |