Catalogue / Gas-insulated switchgear (GIS)
Single-phase encapsulated GIS, Eco seriesSample
by Prithvicore Grid Switchgear (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Prithvicore Grid Switchgear (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
The Eco range of single-phase encapsulated GIS by Prithvicore covers 4 system voltage options (72.5 kV to 420 kV). Design: compact footprint, up to 90% saving, maintenance-free enclosed design and suitable for indoor and outdoor. Used by renewable pooling stations, urban substations and metro rail traction. Designed and tested to IEC 62271-203, IEC 62271-1 and IEC 62271-100. Lead time 40-52 weeks; delivers to East & North-East India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Prithvicore
- Model
- PRI-D32 series
- Listing type
- Product
- Unit
- bay
- Minimum order
- 1 bay
- Lead time
- 40-52 weeks
- Warranty
- 36 months
- Standards
- IEC 62271-203, IEC 62271-1, IEC 62271-100
- Delivers to
- East & North-East India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Drum / reel with end caps
- Delivery terms
- Door delivery in metro cities
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| System voltage72.5 kVPRI-D32-01 | System voltage: 72.5 kV | 1 bay · 40-52 weeks | for verified buyers |
| System voltage145 kVPRI-D32-02 | System voltage: 145 kV | 1 bay · 40-52 weeks | for verified buyers |
| System voltage245 kVPRI-D32-03 | System voltage: 245 kV | 1 bay · 40-52 weeks | for verified buyers |
| System voltage420 kVPRI-D32-04 | System voltage: 420 kV | 1 bay · 40-52 weeks | for verified buyers |
Specifications
| System voltage | 72.5 kV to 420 kV (see variants) |
|---|---|
| Rated current | 1250 A |
| Short-circuit current | 31.5 kA |
| Configuration | Single busmade to order: Double bus / Ring bus |
| Enclosure | Aluminium alloymade to order: Steel |
| Gas | SF6/N2 mixmade to order: SF6 / Clean air |
| Bay width | 800 mmmade to order: 1200 mm / 2500 mm |
| Operating mechanism | Springmade to order: Motor |
| Partial discharge monitoring | UHF sensors |
| Control | Local control cubicle with BCU |
| Gas leakage | < 0.1% per year |
| Earth switches | Maintenance + fast acting |
| Interlocks | Mechanical and electrical |