Catalogue / Gas-insulated switchgear (GIS)
Compact GIS bay for substation, Smart seriesSample
by Rajatline HV Switchgear (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Rajatline HV Switchgear (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Compact GIS bay for substation from Rajatline, Smart series: 4 system voltage options between 36 kV and 245 kV. Design: factory-assembled bays, UHF partial discharge sensors and gas compartment with density monitors. Used by offshore and hilly regions, industrial plants and renewable pooling stations. Designed and tested to IEC 62271-203, IEC 62271-1 and IEC 62271-100. Lead time 20-28 weeks; delivers to All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Rajatline
- Model
- RAJ-7A3 series
- Listing type
- Product
- Unit
- bay
- Minimum order
- 1 bay
- Lead time
- 20-28 weeks
- Warranty
- 36 months
- Standards
- IEC 62271-203, IEC 62271-1, IEC 62271-100
- Delivers to
- All India and export (SAARC, Middle East, Africa)
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Wooden crate, seaworthy
- Delivery terms
- FOR nearest railhead
- Returns
- No returns on made-to-order items
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| System voltage36 kVRAJ-7A3-01 | System voltage: 36 kV | 1 bay · 20-28 weeks | for verified buyers |
| System voltage72.5 kVRAJ-7A3-02 | System voltage: 72.5 kV | 1 bay · 20-28 weeks | for verified buyers |
| System voltage145 kVRAJ-7A3-03 | System voltage: 145 kV | 1 bay · 40-52 weeks | for verified buyers |
| System voltage245 kVRAJ-7A3-04 | System voltage: 245 kV | 1 bay · 40-52 weeks | for verified buyers |
Specifications
| System voltage | 36 kV to 245 kV (see variants) |
|---|---|
| Rated current | 2500 A |
| Short-circuit current | 31.5 kAmade to order: 40 kA / 50 kA |
| Configuration | Ring busmade to order: Single bus / Double bus |
| Enclosure | Steel |
| Gas | SF6made to order: SF6/N2 mix / Clean air |
| Bay width | 800 mm |
| Operating mechanism | Motor |
| Partial discharge monitoring | UHF sensors |
| Control | Local control cubicle with BCU |
| Gas leakage | < 0.1% per year |
| Earth switches | Maintenance + fast acting |
| Interlocks | Mechanical and electrical |