Compact switching assembly from Rajatline, Edge 5 series: 4 system voltage options between 72.5 kV and 420 kV. Key features: combines breaker, disconnector and CT, fewer SF6 joints and seismic qualified. Typically used for brownfield bay additions, seismic zones and pollution and coastal areas. Designed and tested to IEC 62271-100, IEC 62271-108 and IEC 62271-1. Lead time 16-24 weeks; delivers to All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Rajatline
- Model
- RAJ-CB6 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 5 nos
- Lead time
- 16-24 weeks
- Warranty
- 36 months
- Standards
- IEC 62271-100, IEC 62271-108, IEC 62271-1
- Delivers to
- All India and export (SAARC, Middle East, Africa)
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Drum / reel with end caps
- Delivery terms
- FOR site, freight included
- Returns
- Returns within 15 days if unused, in original packing
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| System voltage72.5 kVRAJ-CB6-01 | System voltage: 72.5 kV | 5 nos · 16-24 weeks | for verified buyers |
| System voltage145 kVRAJ-CB6-02 | System voltage: 145 kV | 5 nos · 16-24 weeks | for verified buyers |
| System voltage245 kVRAJ-CB6-03 | System voltage: 245 kV | 5 nos · 28-36 weeks | for verified buyers |
| System voltage420 kVRAJ-CB6-04 | System voltage: 420 kV | 5 nos · 28-36 weeks | for verified buyers |
Specifications
| System voltage | 72.5 kV to 420 kV (see variants) |
|---|---|
| Concept | Hybridmade to order: Dead tank / Compact |
| Rated current | 4000 A |
| Breaking current | 40 kAmade to order: 31.5 kA / 50 kA |
| Gas | SF6-freemade to order: SF6 |
| Integrated CT | Yes, up to 5 cores |
| Integrated disconnector | No |
| Integrated earth switch | Yes |
| Mechanism | Spring |
| Insulation | Air outdoor bushings |
| Footprint saving | 50-70% |
| Operating temp | -30 to 50 deg C |
| Monitoring | Gas density, operation counter |