Catalogue / Substation construction
Pooling substation for renewable projects, Titan 7 seriesSample
by Ravikiran Consultants (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Ravikiran Consultants (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Ravikiran Titan 7 pooling substation for renewable projects, offered in 4 voltage class options from 11 kV to 132 kV. Key features: earth grid designed for fault level and soil resistivity, battery and DC system installation and fire protection and oil soak pits. Typically used for data centre power infrastructure, renewable pooling stations and state utility augmentation. Delivered in line with CEA (Technical Standards for Construction of Electrical Plants) Regulations, IEC 61936-1 and IS 3043 (Earthing). Mobilisation Engineering in 4-6 weeks; serves North India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Ravikiran
- Model
- RAV-DC1 series
- Listing type
- Service
- Unit
- bay
- Minimum order
- 1 bay
- Lead time
- Engineering in 4-6 weeks
- Warranty
- Equipment as per OEM
- Standards
- CEA (Technical Standards for Construction of Electrical Plants) Regulations, IEC 61936-1, IS 3043 (Earthing)
- Delivers to
- North India
- GST rate
- 18 %
- Country of origin
- India
- Delivery terms
- Site mobilisation as per work order
- Returns
- Re-work of defective scope at no cost
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Voltage class11 kVRAV-DC1-01 | Voltage class: 11 kV | 1 bay · Engineering in 4-6 weeks | for verified buyers |
| Voltage class33 kVRAV-DC1-02 | Voltage class: 33 kV | 1 bay · Engineering in 4-6 weeks | for verified buyers |
| Voltage class66 kVRAV-DC1-03 | Voltage class: 66 kV | 1 bay · Execution 6-15 months | for verified buyers |
| Voltage class132 kVRAV-DC1-04 | Voltage class: 132 kV | 1 bay · Execution 6-15 months | for verified buyers |
Specifications
| Voltage class | 11 kV to 132 kV (see variants) |
|---|---|
| Type | Outdoor AIS |
| Scope | Civil and structural |
| Transformers | Up to 160 MVA |
| Earthing | GI flat grid with ground rods |
| Bay count | 6-10 bays |
| Protection scheme | Main-1 and Main-2 relaysmade to order: Numerical busbar protection |
| SCADA and communication | IEC 60870-5-104 |
| Statutory | CEIG inspection support |
| Duration | 6-9 months |
| Payment terms | Percentage on supply, erection |