Catalogue / Transformer overhaul & oil filtration

No photo yet

On-site core and winding inspection, Prime 6 seriesSample

by Ravi Projects (Sample) · verified by BARREL

Price on quote

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Ravi Projects (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Ravi Prime 6 on-site core and winding inspection, offered in 4 transformer rating options from 10 MVA to 100 MVA. Design: leak testing before energisation, nitrogen or dry air purge on opening and hot oil circulation under vacuum. Used by industrial distribution transformers, state utility asset life extension and solar and wind pooling substations. Delivered in line with IS 335 (Mineral Insulating Oil), IS 1866 (Oil Maintenance) and IEC 60422. Mobilisation Planned shutdown required; serves All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Ravi
Model
RAV-1C3 series
Listing type
Service
Unit
nos
Minimum order
1 nos
Lead time
Planned shutdown required
Warranty
Oil quality guarantee 6 months
Standards
IS 335 (Mineral Insulating Oil), IS 1866 (Oil Maintenance), IEC 60422
Delivers to
All India and export (SAARC, Middle East, Africa)
GST rate
18 %
Country of origin
India
Delivery terms
Site mobilisation as per work order
Returns
Re-work of defective scope at no cost
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Transformer rating10 MVARAV-1C3-01Transformer rating: 10 MVA1 nos · Planned shutdown requiredon quote
Transformer rating20 MVARAV-1C3-02Transformer rating: 20 MVA1 nos · Planned shutdown requiredon quote
Transformer rating50 MVARAV-1C3-03Transformer rating: 50 MVA1 nos · Planned shutdown requiredon quote
Transformer rating100 MVARAV-1C3-04Transformer rating: 100 MVA1 nos · Planned shutdown requiredon quote

Specifications

Transformer rating10 MVA to 100 MVA (see variants)
ServiceFull overhaul with rewinding
Filtration machineMobile 12000 L/hr
Oil BDV targetAbove 70 kV
Moisture targetBelow 5 ppmmade to order: Below 10 ppm
TestingFull routine tests after overhaul
SparesBushings and OLTC parts at costmade to order: Gaskets and silica gel
Downtime5-7 days
Site workWorkshop repair
CrewSpecialised overhaul teammade to order: 4 technicians with supervisor
CertificateOverhaul report with test data

BARREL: Bharat Atom Renewable Resources Energy Limited