Ravi Pro 2 substation O&M with 24x7 shift operation, offered in 5 voltage level options from 33 kV to 400 kV. Design: insulator and joint inspection, oil leak and silica gel checks and fault analysis within 24 hours. Used by state utility outsourcing, renewable pooling substations and railway and metro sub-stations. Delivered in line with CEA (Measures relating to Safety) Regulations, CEA (Grid Standards) Regulations and IS 10028 (Transformer Installation). Mobilisation Baseline condition audit first; serves All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Ravi
- Model
- RAV-0A3 series
- Listing type
- Service
- Unit
- month
- Minimum order
- 1 month
- Lead time
- Baseline condition audit first
- Warranty
- Service credits for avoidable outages
- Standards
- CEA (Measures relating to Safety) Regulations, CEA (Grid Standards) Regulations, IS 10028 (Transformer Installation)
- Delivers to
- All India and export (SAARC, Middle East, Africa)
- GST rate
- 18 %
- Country of origin
- India
- Delivery terms
- Site mobilisation as per work order
- Returns
- Re-work of defective scope at no cost
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Voltage level33 kVRAV-0A3-01 | Voltage level: 33 kV | 1 month · Baseline condition audit first | for verified buyers |
| Voltage level66 kVRAV-0A3-02 | Voltage level: 66 kV | 1 month · Baseline condition audit first | for verified buyers |
| Voltage level132 kVRAV-0A3-03 | Voltage level: 132 kV | 1 month · Baseline condition audit first | for verified buyers |
| Voltage level220 kVRAV-0A3-04 | Voltage level: 220 kV | 1 month · Baseline condition audit first | for verified buyers |
| Voltage level400 kVRAV-0A3-05 | Voltage level: 400 kV | 1 month · Baseline condition audit first | for verified buyers |
Specifications
| Voltage level | 33 kV to 400 kV (see variants) |
|---|---|
| Scope | Operation and maintenancemade to order: Maintenance only / Operation, maintenance and statutory compliance |
| Shift pattern | 3 shifts, 24x7 |
| Manpower | Two engineers plus 12 staff |
| Line patrolling | Monthly foot patrolmade to order: Quarterly drone patrol |
| Testing | Thermography twice a yearmade to order: Annual relay and CT/PT test |
| Statutory records | Log books, permits, shutdown registermade to order: CEIG renewal support |
| Spares | Critical spares by ownermade to order: Consumables included |
| Response time | 2 hours for trip |
| Reporting | Real-time dashboardsmade to order: Monthly fault and maintenance report |
| Term | 1 yearmade to order: 3 years |