Catalogue / Power system studies (load flow, short circuit, grid code)

No photo yet

Protection coordination and relay setting, Eco 3 seriesSample

by Ravipushpak Projects (Sample) · verified by BARREL

Price on quote

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Ravipushpak Projects (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

The Eco 3 service of protection coordination and relay setting by Ravipushpak covers 6 network scale options (11 kV plant to 400 kV system). Key features: fault level verification of switchgear, relay setting files ready to load and reactive power capability curves. Suited to renewable developers seeking connectivity, utilities and consultants and industrial plants adding generation. Delivered in line with CEA (Technical Standards for Connectivity) Regulations, Indian Electricity Grid Code and IEEE 1547. Mobilisation 2-6 weeks; serves South India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Ravipushpak
Model
RAV-F17 series
Listing type
Service
Unit
report
Minimum order
1 report
Lead time
2-6 weeks
Warranty
Revision for utility comments
Standards
CEA (Technical Standards for Connectivity) Regulations, Indian Electricity Grid Code, IEEE 1547
Delivers to
South India
GST rate
18 %
Country of origin
India
Delivery terms
Site mobilisation as per work order
Returns
Re-work of defective scope at no cost
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Network scale11 kV plantRAV-F17-01Network scale: 11 kV plant1 report · 2-6 weekson quote
Network scale33 kV plantRAV-F17-02Network scale: 33 kV plant1 report · 2-6 weekson quote
Network scale66 kV systemRAV-F17-03Network scale: 66 kV system1 report · 2-6 weekson quote
Network scale132 kV systemRAV-F17-04Network scale: 132 kV system1 report · 2-6 weekson quote
Network scale220 kV systemRAV-F17-05Network scale: 220 kV system1 report · 2-6 weekson quote
Network scale400 kV systemRAV-F17-06Network scale: 400 kV system1 report · 2-6 weekson quote

Specifications

Network scale11 kV plant to 400 kV system (see variants)
Study typeHarmonicsmade to order: Load flow and short circuit / Dynamic and transient / Protection coordination
SoftwarePSS/Emade to order: ETAP / DIgSILENT PowerFactory
Model dataClient single line diagram and datamade to order: Utility network model
DeliverablesStudy report with results
Grid code checksVoltage and reactive power capabilitymade to order: LVRT/HVRT and ramp rate
ReviewLender reviewmade to order: Utility submission support
ScenariosMultiple dispatch cases
TeamPower system engineer
Turnaround4-6 weeksmade to order: 2-3 weeks
ValidationPeer reviewmade to order: Compared with measured data