Catalogue / Numerical relays

No photo yet

Numerical feeder protection relay, Plus seriesSample

by Sabarmatideep Protection Systems (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Sabarmatideep Protection Systems (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

The Plus range of numerical feeder protection relay by Sabarmatideep covers 5 function options (Overcurrent / earth fault to Line distance). Highlights: self-supervision with watchdog, graphical logic programming and event and fault recorder with 1 ms stamps. Suited to solar plant collector feeders, motor control centres and substation feeders. Designed and tested to IEC 60255, IEC 61850 and IS 3231. Lead time 8-10 weeks; delivers to All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Sabarmatideep
Model
SAB-C45 series
Listing type
Product
Unit
nos
Minimum order
1 nos
Lead time
8-10 weeks
Warranty
36 months
Standards
IEC 60255, IEC 61850, IS 3231
Delivers to
All India and export (SAARC, Middle East, Africa)
GST rate
18 %
Country of origin
India
Packaging
Drum / reel with end caps
Delivery terms
Ex-works, freight extra at actuals
Returns
Returns within 15 days if unused, in original packing
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
FunctionOvercurrent / earth faultSAB-C45-01Function: Overcurrent / earth fault1 nos · 8-10 weeksfor verified buyers
FunctionMotor protectionSAB-C45-02Function: Motor protection1 nos · 8-10 weeksfor verified buyers
FunctionFeeder protectionSAB-C45-03Function: Feeder protection1 nos · 8-10 weeksfor verified buyers
FunctionTransformer differentialSAB-C45-04Function: Transformer differential1 nos · 8-10 weeksfor verified buyers
FunctionLine distanceSAB-C45-05Function: Line distance1 nos · 8-10 weeksfor verified buyers

Specifications

FunctionOvercurrent / earth fault to Line distance (see variants)
Aux supply110 V DC
CT input5 A
VT input63.5 V
Binary inputs32
Output relays6made to order: 12 / 24
CommunicationIEC 61850 Ed 2made to order: Modbus / IEC 60870-5-103
DisplayLCD with keypadmade to order: Graphic LCD
Disturbance recorderUp to 100 records
Accuracy classClass 0.5 metering
CaseDraw-out
Time syncIRIG-Bmade to order: SNTP / PTP
Cyber-securityRole-based access

BARREL: Bharat Atom Renewable Resources Energy Limited