Numerical feeder protection relay, Plus seriesSample
by Sabarmatideep Protection Systems (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Sabarmatideep Protection Systems (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
The Plus range of numerical feeder protection relay by Sabarmatideep covers 5 function options (Overcurrent / earth fault to Line distance). Highlights: self-supervision with watchdog, graphical logic programming and event and fault recorder with 1 ms stamps. Suited to solar plant collector feeders, motor control centres and substation feeders. Designed and tested to IEC 60255, IEC 61850 and IS 3231. Lead time 8-10 weeks; delivers to All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Sabarmatideep
- Model
- SAB-C45 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 1 nos
- Lead time
- 8-10 weeks
- Warranty
- 36 months
- Standards
- IEC 60255, IEC 61850, IS 3231
- Delivers to
- All India and export (SAARC, Middle East, Africa)
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Drum / reel with end caps
- Delivery terms
- Ex-works, freight extra at actuals
- Returns
- Returns within 15 days if unused, in original packing
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| FunctionOvercurrent / earth faultSAB-C45-01 | Function: Overcurrent / earth fault | 1 nos · 8-10 weeks | for verified buyers |
| FunctionMotor protectionSAB-C45-02 | Function: Motor protection | 1 nos · 8-10 weeks | for verified buyers |
| FunctionFeeder protectionSAB-C45-03 | Function: Feeder protection | 1 nos · 8-10 weeks | for verified buyers |
| FunctionTransformer differentialSAB-C45-04 | Function: Transformer differential | 1 nos · 8-10 weeks | for verified buyers |
| FunctionLine distanceSAB-C45-05 | Function: Line distance | 1 nos · 8-10 weeks | for verified buyers |
Specifications
| Function | Overcurrent / earth fault to Line distance (see variants) |
|---|---|
| Aux supply | 110 V DC |
| CT input | 5 A |
| VT input | 63.5 V |
| Binary inputs | 32 |
| Output relays | 6made to order: 12 / 24 |
| Communication | IEC 61850 Ed 2made to order: Modbus / IEC 60870-5-103 |
| Display | LCD with keypadmade to order: Graphic LCD |
| Disturbance recorder | Up to 100 records |
| Accuracy class | Class 0.5 metering |
| Case | Draw-out |
| Time sync | IRIG-Bmade to order: SNTP / PTP |
| Cyber-security | Role-based access |