Catalogue / Transmission line erection & stringing

No photo yet

66 kV and 132 kV line construction, Eco 2 seriesSample

by Sabarmati Engineering Services (Sample) · verified by BARREL

Price on quote

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Sabarmati Engineering Services (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Sabarmati Eco 2 66 kV and 132 kV line construction, offered in 4 voltage level options from 66 kV to 400 kV. Design: foundation concrete cube testing, sag and tension charts for stringing and tower verticality and bolt tightening records. Typically used for state transmission utilities, solar and wind evacuation lines and railway traction feed. Delivered in line with IS 802 (Overhead Line Towers), IS 2713 (Steel Tubular Poles) and CEA (Measures relating to Safety) Regulations. Mobilisation Per section schedule; serves All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Sabarmati
Model
SAB-7B7 series
Listing type
Service
Unit
km
Minimum order
1 km
Lead time
Per section schedule
Warranty
Defect liability 24 months
Standards
IS 802 (Overhead Line Towers), IS 2713 (Steel Tubular Poles), CEA (Measures relating to Safety) Regulations
Delivers to
All India and export (SAARC, Middle East, Africa)
GST rate
18 %
Country of origin
India
Delivery terms
Site mobilisation as per work order
Returns
Re-work of defective scope at no cost
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Voltage level66 kVSAB-7B7-01Voltage level: 66 kV1 km · Per section scheduleon quote
Voltage level132 kVSAB-7B7-02Voltage level: 132 kV1 km · Per section scheduleon quote
Voltage level220 kVSAB-7B7-03Voltage level: 220 kV1 km · Per section scheduleon quote
Voltage level400 kVSAB-7B7-04Voltage level: 400 kV1 km · Per section scheduleon quote

Specifications

Voltage level66 kV to 400 kV (see variants)
Circuit typeSingle circuit
ConductorACSR Panther
ScopeErection and stringing only
Stringing methodTension stringingmade to order: Conventional stringing
CrewTwo erection gangs plus foundation team
Tower testingPrototype test witnessed
Productivity1-1.5 km per week
Approvals supportPTCC clearance and RoW
SafetyFall protection and line clearance
InsuranceCAR and workmen compensationmade to order: Third-party liability

BARREL: Bharat Atom Renewable Resources Energy Limited