Catalogue / Transmission line erection & stringing
66 kV and 132 kV line construction, Eco 2 seriesSample
by Sabarmati Engineering Services (Sample) · verified by BARREL
Price on quote
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Sabarmati Engineering Services (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Sabarmati Eco 2 66 kV and 132 kV line construction, offered in 4 voltage level options from 66 kV to 400 kV. Design: foundation concrete cube testing, sag and tension charts for stringing and tower verticality and bolt tightening records. Typically used for state transmission utilities, solar and wind evacuation lines and railway traction feed. Delivered in line with IS 802 (Overhead Line Towers), IS 2713 (Steel Tubular Poles) and CEA (Measures relating to Safety) Regulations. Mobilisation Per section schedule; serves All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Sabarmati
- Model
- SAB-7B7 series
- Listing type
- Service
- Unit
- km
- Minimum order
- 1 km
- Lead time
- Per section schedule
- Warranty
- Defect liability 24 months
- Standards
- IS 802 (Overhead Line Towers), IS 2713 (Steel Tubular Poles), CEA (Measures relating to Safety) Regulations
- Delivers to
- All India and export (SAARC, Middle East, Africa)
- GST rate
- 18 %
- Country of origin
- India
- Delivery terms
- Site mobilisation as per work order
- Returns
- Re-work of defective scope at no cost
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Voltage level66 kVSAB-7B7-01 | Voltage level: 66 kV | 1 km · Per section schedule | on quote |
| Voltage level132 kVSAB-7B7-02 | Voltage level: 132 kV | 1 km · Per section schedule | on quote |
| Voltage level220 kVSAB-7B7-03 | Voltage level: 220 kV | 1 km · Per section schedule | on quote |
| Voltage level400 kVSAB-7B7-04 | Voltage level: 400 kV | 1 km · Per section schedule | on quote |
Specifications
| Voltage level | 66 kV to 400 kV (see variants) |
|---|---|
| Circuit type | Single circuit |
| Conductor | ACSR Panther |
| Scope | Erection and stringing only |
| Stringing method | Tension stringingmade to order: Conventional stringing |
| Crew | Two erection gangs plus foundation team |
| Tower testing | Prototype test witnessed |
| Productivity | 1-1.5 km per week |
| Approvals support | PTCC clearance and RoW |
| Safety | Fall protection and line clearance |
| Insurance | CAR and workmen compensationmade to order: Third-party liability |