Catalogue / Substation & line O&M
Battery bank and DC system maintenance, Eco 3 seriesSample
by Sahyadriakshay Engineering Services (Sample) · verified by BARREL
Price on quote
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Sahyadriakshay Engineering Services (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Sahyadriakshay Eco 3 battery bank and DC system maintenance, offered in 3 voltage level options from 66 kV to 220 kV. Highlights: insulator and joint inspection, oil leak and silica gel checks and outage planning with the utility. Suited to railway and metro sub-stations, renewable pooling substations and industrial captive substations. Delivered in line with CEA (Measures relating to Safety) Regulations, CEA (Grid Standards) Regulations and IS 10028 (Transformer Installation). Mobilisation Baseline condition audit first; serves West India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Sahyadriakshay
- Model
- SAH-CB9 series
- Listing type
- Service
- Unit
- month
- Minimum order
- 1 month
- Lead time
- Baseline condition audit first
- Warranty
- As per contract
- Standards
- CEA (Measures relating to Safety) Regulations, CEA (Grid Standards) Regulations, IS 10028 (Transformer Installation)
- Delivers to
- West India
- GST rate
- 18 %
- Country of origin
- India
- Delivery terms
- Site mobilisation as per work order
- Returns
- Re-work of defective scope at no cost
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Voltage level66 kVSAH-CB9-01 | Voltage level: 66 kV | 1 month · Baseline condition audit first | on quote |
| Voltage level132 kVSAH-CB9-02 | Voltage level: 132 kV | 1 month · Baseline condition audit first | on quote |
| Voltage level220 kVSAH-CB9-03 | Voltage level: 220 kV | 1 month · Baseline condition audit first | on quote |
Specifications
| Voltage level | 66 kV to 220 kV (see variants) |
|---|---|
| Scope | Operation, maintenance and statutory compliancemade to order: Operation and maintenance / Maintenance only |
| Shift pattern | General shift plus on-call |
| Manpower | Engineer plus 6 operatorsmade to order: Two engineers plus 12 staff |
| Line patrolling | Monthly foot patrol |
| Testing | Annual relay and CT/PT test |
| Statutory records | CEIG renewal supportmade to order: Log books, permits, shutdown register |
| Spares | Consumables includedmade to order: Critical spares by owner |
| Response time | 2 hours for tripmade to order: 4 hours |
| Reporting | Real-time dashboardsmade to order: Monthly fault and maintenance report |
| Term | 3 yearsmade to order: 1 year |