Catalogue / Thermography & condition monitoring
Infrared thermography survey, Xtra 8 seriesSample
by Sahyadriakshay Engineering Services (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Sahyadriakshay Engineering Services (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
The Xtra 8 service of infrared thermography survey by Sahyadriakshay covers 6 asset size options (1 MW to 100 MW). Highlights: load condition recorded with each scan, priority list of defects with repair advice and hotspot location tagged with GPS. Used by solar plants (module and string hotspots), industrial MCC panels and wind turbine electrical systems. Delivered in line with ISO 18434-1, IEC 62446-3 and IEEE 1584. Mobilisation Report in 5-10 days; serves West India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Sahyadriakshay
- Model
- SAH-539 series
- Listing type
- Service
- Unit
- site
- Minimum order
- 1 site
- Lead time
- Report in 5-10 days
- Warranty
- Re-scan of repaired points at no cost
- Standards
- ISO 18434-1, IEC 62446-3, IEEE 1584
- Delivers to
- West India
- GST rate
- 18 %
- Country of origin
- India (imported sub-assemblies)
- Delivery terms
- Site mobilisation as per work order
- Returns
- Re-work of defective scope at no cost
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Asset size1 MWSAH-539-01 | Asset size: 1 MW | 1 site · Report in 5-10 days | for verified buyers |
| Asset size5 MWSAH-539-02 | Asset size: 5 MW | 1 site · Report in 5-10 days | for verified buyers |
| Asset size10 MWSAH-539-03 | Asset size: 10 MW | 1 site · Report in 5-10 days | for verified buyers |
| Asset size25 MWSAH-539-04 | Asset size: 25 MW | 1 site · Report in 5-10 days | for verified buyers |
| Asset size50 MWSAH-539-05 | Asset size: 50 MW | 1 site · Report in 5-10 days | for verified buyers |
| Asset size100 MWSAH-539-06 | Asset size: 100 MW | 1 site · Report in 5-10 days | for verified buyers |
Specifications
| Asset size | 1 MW to 100 MW (see variants) |
|---|---|
| Technique | Vibration analysis |
| Camera resolution | 640x480 radiometric |
| Deliverable | Annotated hotspot report |
| Drone services | Ground sampling 3 cm per pixel |
| Defect classification | Per client maintenance policy |
| Team | Level II thermographer |
| Certification | ISO 18436-7 trainedmade to order: Technicians with ASNT level II |
| Turnaround | Report in 10 daysmade to order: Report in 5 days |
| Frequency | One-time |
| Software | Cloud dashboard with trend history |