Busbar protection relay, Flex seriesSample
by Sahyadri Protection Systems (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Sahyadri Protection Systems (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
The Flex range of busbar protection relay by Sahyadri covers 6 function options (Overcurrent / earth fault to Busbar differential). Design: multiple setting groups, event and fault recorder with 1 ms stamps and breaker failure and trip circuit supervision. Suited to substation feeders, solar plant collector feeders and industrial incomers. Designed and tested to IEC 60255, IEC 61850 and IS 3231. Lead time 8-10 weeks; delivers to North India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Sahyadri
- Model
- SAH-9E3 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 1 nos
- Lead time
- 8-10 weeks
- Warranty
- 36 months
- Standards
- IEC 60255, IEC 61850, IS 3231
- Delivers to
- North India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Steel skid with shrink wrap
- Delivery terms
- FOR nearest railhead
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| FunctionOvercurrent / earth faultSAH-9E3-01 | Function: Overcurrent / earth fault | 1 nos · 8-10 weeks | for verified buyers |
| FunctionMotor protectionSAH-9E3-02 | Function: Motor protection | 1 nos · 8-10 weeks | for verified buyers |
| FunctionFeeder protectionSAH-9E3-03 | Function: Feeder protection | 1 nos · 8-10 weeks | for verified buyers |
| FunctionTransformer differentialSAH-9E3-04 | Function: Transformer differential | 1 nos · 8-10 weeks | for verified buyers |
| FunctionLine distanceSAH-9E3-05 | Function: Line distance | 1 nos · 8-10 weeks | for verified buyers |
| FunctionBusbar differentialSAH-9E3-06 | Function: Busbar differential | 1 nos · 8-10 weeks | for verified buyers |
Specifications
| Function | Overcurrent / earth fault to Busbar differential (see variants) |
|---|---|
| Aux supply | 24-250 V DC |
| CT input | 1/5 A selectable |
| VT input | 63.5 V |
| Binary inputs | 32made to order: 8 / 16 |
| Output relays | 6made to order: 12 / 24 |
| Communication | Modbusmade to order: IEC 61850 Ed 2 / IEC 60870-5-103 |
| Display | Graphic LCDmade to order: LCD with keypad |
| Disturbance recorder | Up to 100 records |
| Accuracy class | Class 0.5 metering |
| Case | Draw-out |
| Time sync | IRIG-Bmade to order: SNTP / PTP |
| Cyber-security | Role-based access |