Catalogue / Gas-insulated switchgear (GIS)

No photo yet

Three-phase encapsulated GIS, Xtra seriesSample

by Sahyadritamra HV Switchgear (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Sahyadritamra HV Switchgear (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

Sahyadritamra Xtra three-phase encapsulated GIS, offered in 5 system voltage options from 36 kV to 420 kV. Highlights: maintenance-free enclosed design, suitable for indoor and outdoor and factory-assembled bays. Suited to renewable pooling stations, offshore and hilly regions and metro rail traction. Designed and tested to IEC 62271-203, IEC 62271-1 and IEC 62271-100. Lead time 40-52 weeks; delivers to All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Sahyadritamra
Model
SAH-AC6 series
Listing type
Product
Unit
bay
Minimum order
1 bay
Lead time
40-52 weeks
Warranty
36 months
Standards
IEC 62271-203, IEC 62271-1, IEC 62271-100
Delivers to
All India and export (SAARC, Middle East, Africa)
GST rate
18 %
Country of origin
India
Packaging
Corrugated box on pallet
Delivery terms
Ex-works, freight extra at actuals
Returns
Returns within 15 days if unused, in original packing
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
System voltage36 kVSAH-AC6-01System voltage: 36 kV1 bay · 40-52 weeksfor verified buyers
System voltage72.5 kVSAH-AC6-02System voltage: 72.5 kV1 bay · 40-52 weeksfor verified buyers
System voltage145 kVSAH-AC6-03System voltage: 145 kV1 bay · 40-52 weeksfor verified buyers
System voltage245 kVSAH-AC6-04System voltage: 245 kV1 bay · 40-52 weeksfor verified buyers
System voltage420 kVSAH-AC6-05System voltage: 420 kV1 bay · 40-52 weeksfor verified buyers

Specifications

System voltage36 kV to 420 kV (see variants)
Rated current4000 Amade to order: 1250 A / 2500 A / 3150 A
Short-circuit current31.5 kA
ConfigurationRing bus
EnclosureAluminium alloymade to order: Steel
GasSF6/N2 mixmade to order: SF6 / Clean air
Bay width2500 mm
Operating mechanismMotormade to order: Spring
Partial discharge monitoringUHF sensors
ControlLocal control cubicle with BCU
Gas leakage< 0.1% per year
Earth switchesMaintenance + fast acting
InterlocksMechanical and electrical

BARREL: Bharat Atom Renewable Resources Energy Limited