Sahyadritamra Xtra three-phase encapsulated GIS, offered in 5 system voltage options from 36 kV to 420 kV. Highlights: maintenance-free enclosed design, suitable for indoor and outdoor and factory-assembled bays. Suited to renewable pooling stations, offshore and hilly regions and metro rail traction. Designed and tested to IEC 62271-203, IEC 62271-1 and IEC 62271-100. Lead time 40-52 weeks; delivers to All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Sahyadritamra
- Model
- SAH-AC6 series
- Listing type
- Product
- Unit
- bay
- Minimum order
- 1 bay
- Lead time
- 40-52 weeks
- Warranty
- 36 months
- Standards
- IEC 62271-203, IEC 62271-1, IEC 62271-100
- Delivers to
- All India and export (SAARC, Middle East, Africa)
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Corrugated box on pallet
- Delivery terms
- Ex-works, freight extra at actuals
- Returns
- Returns within 15 days if unused, in original packing
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| System voltage36 kVSAH-AC6-01 | System voltage: 36 kV | 1 bay · 40-52 weeks | for verified buyers |
| System voltage72.5 kVSAH-AC6-02 | System voltage: 72.5 kV | 1 bay · 40-52 weeks | for verified buyers |
| System voltage145 kVSAH-AC6-03 | System voltage: 145 kV | 1 bay · 40-52 weeks | for verified buyers |
| System voltage245 kVSAH-AC6-04 | System voltage: 245 kV | 1 bay · 40-52 weeks | for verified buyers |
| System voltage420 kVSAH-AC6-05 | System voltage: 420 kV | 1 bay · 40-52 weeks | for verified buyers |
Specifications
| System voltage | 36 kV to 420 kV (see variants) |
|---|---|
| Rated current | 4000 Amade to order: 1250 A / 2500 A / 3150 A |
| Short-circuit current | 31.5 kA |
| Configuration | Ring bus |
| Enclosure | Aluminium alloymade to order: Steel |
| Gas | SF6/N2 mixmade to order: SF6 / Clean air |
| Bay width | 2500 mm |
| Operating mechanism | Motormade to order: Spring |
| Partial discharge monitoring | UHF sensors |
| Control | Local control cubicle with BCU |
| Gas leakage | < 0.1% per year |
| Earth switches | Maintenance + fast acting |