The Eco range of air circuit breaker (ACB) by Samarthmax covers 5 rating options (100 A to 2500 A). Design: adjustable overload and short-circuit trip settings, high breaking capacity with current limiting action and full range of rated currents from 6 A to 6300 A. Used by building main incomers, LT panels and distribution boards and motor and feeder protection. Designed and tested to IS/IEC 60947-2, IS/IEC 60898-1 and IS 13947 (Part 2). Lead time 3-5 weeks; delivers to North India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Samarthmax
- Model
- SAM-617 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 5 nos
- Lead time
- 3-5 weeks
- Warranty
- 24 months from supply
- Standards
- IS/IEC 60947-2, IS/IEC 60898-1, IS 13947 (Part 2)
- Delivers to
- North India
- GST rate
- 18 %
- Country of origin
- India (imported sub-assemblies)
- Packaging
- Corrugated box on pallet
- Delivery terms
- FOR nearest railhead
- Returns
- Returns within 15 days if unused, in original packing
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Rating100 ASAM-617-01 | Rating: 100 A | 5 nos · 3-5 weeks | for verified buyers |
| Rating250 ASAM-617-02 | Rating: 250 A | 5 nos · 3-5 weeks | for verified buyers |
| Rating630 ASAM-617-03 | Rating: 630 A | 5 nos · 3-5 weeks | for verified buyers |
| Rating1250 ASAM-617-04 | Rating: 1250 A | 5 nos · 3-5 weeks | for verified buyers |
| Rating2500 ASAM-617-05 | Rating: 2500 A | 5 nos · 3-5 weeks | for verified buyers |
Specifications
| Rating | 100 A to 2500 A (see variants) |
|---|---|
| Breaker type | MCBmade to order: MCCB / ACB |
| Poles | 4Pmade to order: 1P / 2P / 3P |
| Rated voltage | 415 V AC |
| Breaking capacity (Icu) | 85 kA |
| Trip unit | Electronic LSIG |
| Tripping curve | D |
| Mounting | Draw-out |
| Utilisation category | Bmade to order: A |
| Communication | Modbus TCPmade to order: None / Modbus RTU |
| Shunt trip / UVR | Optional |
| Terminal type | Lug / busbarmade to order: Box clamp |
| Frequency | 50 Hz |