Catalogue / VCB panels

No photo yet

Indoor vacuum circuit breaker panel, Eco 6 seriesSample

by Samarthmax Switchboards (Sample) · verified by BARREL

Price on quote

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Samarthmax Switchboards (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

The Eco 6 range of indoor vacuum circuit breaker panel by Samarthmax covers 6 rating options (11 kV 630 A to 33 kV 1250 A). Design: front-access design suitable for wall mounting, cable chamber with space for CTs and surge arresters and withdrawable truck with service, test and isolated positions. Suited to industrial HT incomers, large commercial building HT rooms and discom 11/33 kV substations. Designed and tested to IS 13118, IEC 62271-100 and IEC 62271-200. Lead time 4-6 weeks; delivers to North India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Samarthmax
Model
SAM-B73 series
Listing type
Product
Unit
nos
Minimum order
1 nos
Lead time
4-6 weeks
Warranty
18 months from supply
Standards
IS 13118, IEC 62271-100, IEC 62271-200
Delivers to
North India
GST rate
18 %
Country of origin
India (imported sub-assemblies)
Packaging
As per item, transit-safe
Delivery terms
Door delivery in metro cities
Returns
No returns on made-to-order items
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Rating11 kV 630 ASAM-B73-01Rating: 11 kV 630 A1 nos · 4-6 weekson quote
Rating11 kV 1250 ASAM-B73-02Rating: 11 kV 1250 A1 nos · 4-6 weekson quote
Rating11 kV 2000 ASAM-B73-03Rating: 11 kV 2000 A1 nos · 4-6 weekson quote
Rating22 kV 630 ASAM-B73-04Rating: 22 kV 630 A1 nos · 4-6 weekson quote
Rating33 kV 630 ASAM-B73-05Rating: 33 kV 630 A1 nos · 8-10 weekson quote
Rating33 kV 1250 ASAM-B73-06Rating: 33 kV 1250 A1 nos · 8-10 weekson quote

Specifications

Rating11 kV 630 A to 33 kV 1250 A (see variants)
Short-circuit rating40 kA/3 smade to order: 20 kA/3 s / 25 kA/3 s / 31.5 kA/3 s
ConstructionMetal-enclosed fixed
Breaker operating dutyO-0.3 s-CO-3 min-CO
Control voltage220 V DC
Spring charging motor110 V DC
Protection relayNumerical feeder protection relaymade to order: Numerical IDMT O/C-E/F relay
Busbar materialAluminiummade to order: Electrolytic grade copper
Degree of protectionIP42
Internal arc classificationIAC AFLR 25 kA 1 s
Insulation level28 kV / 75 kVp
Frequency50 Hz
Panel finishRAL 7032 powder coat