Catalogue / Field instruments (pressure, temperature, flow, level)
Smart pressure transmitter, Pro seriesSample
by Satavahana Controls (Sample) · verified by BARREL
Price on quote
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Satavahana Controls (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Satavahana Pro smart pressure transmitter, offered in 3 range / size options from 0-100 bar / DN80 to 0-600 bar / DN150. Highlights: self-diagnostics and failure alarms, rotatable housing with local display and stainless steel wetted parts for aggressive media. Typically used for boiler and turbine instrumentation, water and cooling circuits and fuel oil and gas handling. Designed and tested to IEC 61298, IEC 60079-0 and IEC 61508. Lead time 6-8 weeks; delivers to All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Satavahana
- Model
- SAT-5A6 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 1 nos
- Lead time
- 6-8 weeks
- Warranty
- 18 months from supply
- Standards
- IEC 61298, IEC 60079-0, IEC 61508
- Delivers to
- All India and export (SAARC, Middle East, Africa)
- GST rate
- 18 %
- Country of origin
- India (imported sub-assemblies)
- Packaging
- As per item, transit-safe
- Delivery terms
- Ex-works, freight extra at actuals
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Range / size0-100 bar / DN80SAT-5A6-01 | Range / size: 0-100 bar / DN80 | 1 nos · 6-8 weeks | on quote |
| Range / size0-250 bar / DN100SAT-5A6-02 | Range / size: 0-250 bar / DN100 | 1 nos · 6-8 weeks | on quote |
| Range / size0-600 bar / DN150SAT-5A6-03 | Range / size: 0-600 bar / DN150 | 1 nos · 6-8 weeks | on quote |
Specifications
| Range / size | 0-100 bar / DN80 to 0-600 bar / DN150 (see variants) |
|---|---|
| Output | FOUNDATION Fieldbusmade to order: 4-20 mA + HART / Profibus PA |
| Accuracy | ±0.25%made to order: ±0.075% / ±0.1% |
| Process connection | 1/2 NPT(F) |
| Wetted material | Tantalum |
| Supply | 24 VDC loop powered |
| Ingress protection | IP67made to order: IP66 |
| Hazardous area | Ex ia |
| Display | LCD with local keys |
| Process temperature | -40 to 250 °C |
| Calibration | Traceable certificate |
| Housing | SS 316 |