Redundant PLC for process control, Flex 5 seriesSample
by Satavahana Controls (Sample) · verified by BARREL
Price on quote
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Satavahana Controls (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
The Flex 5 range of redundant PLC for process control by Satavahana covers 4 i/O points options (128 I/O to 1024 I/O). Design: integrated safety (SIL 2/3) option, firmware with cyber-security hardening and hot-swappable I/O modules. Suited to power plant balance-of-plant control, water treatment and utilities and substation and process automation. Designed and tested to IEC 61131-2, IEC 61131-3 and IEC 61508 (SIL 2/3). Lead time 4-6 weeks; delivers to All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Satavahana
- Model
- SAT-068 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 1 nos
- Lead time
- 4-6 weeks
- Warranty
- 24 months from supply
- Standards
- IEC 61131-2, IEC 61131-3, IEC 61508 (SIL 2/3)
- Delivers to
- All India and export (SAARC, Middle East, Africa)
- GST rate
- 18 %
- Country of origin
- India (imported sub-assemblies)
- Packaging
- Steel skid with shrink wrap
- Delivery terms
- FOR site, freight included
- Returns
- No returns on made-to-order items
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| I/O points128 I/OSAT-068-01 | I/O points: 128 I/O | 1 nos · 4-6 weeks | on quote |
| I/O points256 I/OSAT-068-02 | I/O points: 256 I/O | 1 nos · 4-6 weeks | on quote |
| I/O points512 I/OSAT-068-03 | I/O points: 512 I/O | 1 nos · 8-12 weeks | on quote |
| I/O points1024 I/OSAT-068-04 | I/O points: 1024 I/O | 1 nos · 8-12 weeks | on quote |
Specifications
| I/O points | 128 I/O to 1024 I/O (see variants) |
|---|---|
| CPU memory | 512 KB |
| Scan time | < 1 ms per 1k instructionsmade to order: < 0.1 ms per 1k |
| Redundancy | Nonemade to order: Hot standby CPU and network |
| Programming | IEC 61131-3 (LD, FBD, ST) |
| Communication | Profinetmade to order: Modbus TCP / Ethernet/IP / Profibus DP |
| Digital input | 24 VDC sink/source |
| Analog input | RTD/TC |
| Power supply | 24 VDCmade to order: 110-230 VAC |
| Operating temperature | -25 to 70 °C |
| Hot swap | Yes, I/O modules |
| Security | Password + access control, firmware signing |