Catalogue / Substation construction
33/132 kV AIS substation construction, Neo seriesSample
by Satavahanakelvin Consultants (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Satavahanakelvin Consultants (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Satavahanakelvin Neo 33/132 kV AIS substation construction, offered in 5 voltage class options from 33 kV to 400 kV. Design: battery and DC system installation, full documentation pack and as-built and earth grid designed for fault level and soil resistivity. Typically used for renewable pooling stations, data centre power infrastructure and industrial captive substations. Delivered in line with CEA (Technical Standards for Construction of Electrical Plants) Regulations, IEC 61936-1 and IS 3043 (Earthing). Mobilisation Execution 6-15 months; serves All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Satavahanakelvin
- Model
- SAT-369 series
- Listing type
- Service
- Unit
- bay
- Minimum order
- 1 bay
- Lead time
- Execution 6-15 months
- Warranty
- Defect liability 24 months
- Standards
- CEA (Technical Standards for Construction of Electrical Plants) Regulations, IEC 61936-1, IS 3043 (Earthing)
- Delivers to
- All India
- GST rate
- 18 %
- Country of origin
- India
- Delivery terms
- Site mobilisation as per work order
- Returns
- Re-work of defective scope at no cost
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Voltage class33 kVSAT-369-01 | Voltage class: 33 kV | 1 bay · Execution 6-15 months | for verified buyers |
| Voltage class66 kVSAT-369-02 | Voltage class: 66 kV | 1 bay · Execution 6-15 months | for verified buyers |
| Voltage class132 kVSAT-369-03 | Voltage class: 132 kV | 1 bay · Execution 6-15 months | for verified buyers |
| Voltage class220 kVSAT-369-04 | Voltage class: 220 kV | 1 bay · Execution 6-15 months | for verified buyers |
| Voltage class400 kVSAT-369-05 | Voltage class: 400 kV | 1 bay · Execution 6-15 months | for verified buyers |
Specifications
| Voltage class | 33 kV to 400 kV (see variants) |
|---|---|
| Type | Indoor GISmade to order: Outdoor AIS / Hybrid GIS |
| Scope | Full turnkey |
| Transformers | Up to 50 MVAmade to order: Up to 160 MVA / Up to 315 MVA |
| Earthing | Copper-bonded rods |
| Bay count | 6-10 baysmade to order: 2-4 bays |
| Protection scheme | Numerical busbar protectionmade to order: Main-1 and Main-2 relays |
| SCADA and communication | IEC 61850 compliant |
| Statutory | CEIG inspection supportmade to order: STU charging approval |
| Duration | 6-9 monthsmade to order: 12-15 months |
| Payment terms | Percentage on supply, erectionmade to order: Milestone: 10/70/10/10 |