Catalogue / Aspirating smoke detection

No photo yet

Aspirating smoke detection (ASD) unit, Prime seriesSample

by Satavahanaspark Fire Systems (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Satavahanaspark Fire Systems (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

Aspirating smoke detection (ASD) unit from Satavahanaspark, Prime series: 4 coverage options between Up to 500 m² / 2 pipes and Up to 4000 m². Design: four alarm levels for graded response, integration with gas suppression panel and detects incipient fire at very low smoke densities. Suited to data centres and control rooms, battery energy storage containers and high-bay warehouses. Designed and tested to EN 54-20, NFPA 76 and NFPA 72. Lead time 3-4 weeks; delivers to South India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Satavahanaspark
Model
SAT-5C2 series
Listing type
Product
Unit
nos
Minimum order
2 nos
Lead time
3-4 weeks
Warranty
36 months from supply
Standards
EN 54-20, NFPA 76, NFPA 72
Delivers to
South India
GST rate
18 %
Country of origin
India
Packaging
Wooden crate, seaworthy
Delivery terms
FOR nearest railhead
Returns
Replacement of items damaged in transit within 7 days
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
CoverageUp to 500 m² / 2 pipesSAT-5C2-01Coverage: Up to 500 m² / 2 pipes2 nos · 3-4 weeksfor verified buyers
CoverageUp to 1000 m² / 4 pipesSAT-5C2-02Coverage: Up to 1000 m² / 4 pipes2 nos · 3-4 weeksfor verified buyers
CoverageUp to 2000 m²SAT-5C2-03Coverage: Up to 2000 m²2 nos · 6-8 weeksfor verified buyers
CoverageUp to 4000 m²SAT-5C2-04Coverage: Up to 4000 m²2 nos · 6-8 weeksfor verified buyers

Specifications

CoverageUp to 500 m² / 2 pipes to Up to 4000 m² (see variants)
SensitivityClass A (very high)
DetectionLaser light scattering
Alarm levelsAlert, Action, Fire 1, Fire 2
Pipe networkUp to 100 mmade to order: Up to 400 m
Sampling holesUp to 40
Airflow monitoringYes, with fault alarm
Relays5
CommunicationEthernetmade to order: RS-485 / Modbus
Power supply24 VDC
Dust filterReplaceable
Operating temperature-10 to 39 °C
ApprovalUL 268made to order: EN 54-20

BARREL: Bharat Atom Renewable Resources Energy Limited