Catalogue / Synchronising panels
Genset paralleling switchgear, Neo seriesSample
by Satpura Motors & Gensets (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Satpura Motors & Gensets (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
The Neo range of genset paralleling switchgear by Satpura covers 5 gensets in parallel options (2 gensets to 8 gensets). Design: dead bus closing logic, kW and kVAR load sharing and remote status via SCADA. Used by hospitals and industries, power plants with parallel DG and multi-genset data centres. Designed and tested to IEC 61439-2, IS 8623 and IEC 60947-2. Lead time 4-6 weeks; delivers to All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Satpura
- Model
- SAT-BD2 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 5 nos
- Lead time
- 4-6 weeks
- Warranty
- 12 months
- Standards
- IEC 61439-2, IS 8623, IEC 60947-2
- Delivers to
- All India and export (SAARC, Middle East, Africa)
- GST rate
- 18 %
- Country of origin
- India (imported sub-assemblies)
- Packaging
- Wooden crate, seaworthy
- Delivery terms
- Door delivery in metro cities
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Gensets in parallel2 gensetsSAT-BD2-01 | Gensets in parallel: 2 gensets | 5 nos · 4-6 weeks | for verified buyers |
| Gensets in parallel3 gensetsSAT-BD2-02 | Gensets in parallel: 3 gensets | 5 nos · 4-6 weeks | for verified buyers |
| Gensets in parallel4 gensetsSAT-BD2-03 | Gensets in parallel: 4 gensets | 5 nos · 4-6 weeks | for verified buyers |
| Gensets in parallel6 gensetsSAT-BD2-04 | Gensets in parallel: 6 gensets | 5 nos · 8-12 weeks | for verified buyers |
| Gensets in parallel8 gensetsSAT-BD2-05 | Gensets in parallel: 8 gensets | 5 nos · 8-12 weeks | for verified buyers |
Specifications
| Gensets in parallel | 2 gensets to 8 gensets (see variants) |
|---|---|
| Bus rating | 4000 A |
| Voltage | 415 V |
| Fault level | 50 kAmade to order: 65 kA / 85 kA |
| Controller | PLC master |
| Breaker | ACB |
| Load sharing | Droopmade to order: Isochronous |
| Protections | Reverse power, overcurrent, earth fault |
| Communication | Modbus |
| Form of separation | Form 3bmade to order: Form 4b |
| Enclosure | IP42 |
| Mains parallel | Yes |