Catalogue / Synchronising panels

No photo yet

Genset paralleling switchgear, Neo seriesSample

by Satpura Motors & Gensets (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Satpura Motors & Gensets (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

The Neo range of genset paralleling switchgear by Satpura covers 5 gensets in parallel options (2 gensets to 8 gensets). Design: dead bus closing logic, kW and kVAR load sharing and remote status via SCADA. Used by hospitals and industries, power plants with parallel DG and multi-genset data centres. Designed and tested to IEC 61439-2, IS 8623 and IEC 60947-2. Lead time 4-6 weeks; delivers to All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Satpura
Model
SAT-BD2 series
Listing type
Product
Unit
nos
Minimum order
5 nos
Lead time
4-6 weeks
Warranty
12 months
Standards
IEC 61439-2, IS 8623, IEC 60947-2
Delivers to
All India and export (SAARC, Middle East, Africa)
GST rate
18 %
Country of origin
India (imported sub-assemblies)
Packaging
Wooden crate, seaworthy
Delivery terms
Door delivery in metro cities
Returns
Replacement of items damaged in transit within 7 days
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Gensets in parallel2 gensetsSAT-BD2-01Gensets in parallel: 2 gensets5 nos · 4-6 weeksfor verified buyers
Gensets in parallel3 gensetsSAT-BD2-02Gensets in parallel: 3 gensets5 nos · 4-6 weeksfor verified buyers
Gensets in parallel4 gensetsSAT-BD2-03Gensets in parallel: 4 gensets5 nos · 4-6 weeksfor verified buyers
Gensets in parallel6 gensetsSAT-BD2-04Gensets in parallel: 6 gensets5 nos · 8-12 weeksfor verified buyers
Gensets in parallel8 gensetsSAT-BD2-05Gensets in parallel: 8 gensets5 nos · 8-12 weeksfor verified buyers

Specifications

Gensets in parallel2 gensets to 8 gensets (see variants)
Bus rating4000 A
Voltage415 V
Fault level50 kAmade to order: 65 kA / 85 kA
ControllerPLC master
BreakerACB
Load sharingDroopmade to order: Isochronous
ProtectionsReverse power, overcurrent, earth fault
CommunicationModbus
Form of separationForm 3bmade to order: Form 4b
EnclosureIP42
Mains parallelYes