Catalogue / Power system studies (load flow, short circuit, grid code)
Grid code compliance study, Edge seriesSample
by Satpura Projects (Sample) · verified by BARREL
Price on quote
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Satpura Projects (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Satpura Edge grid code compliance study, offered in 3 network scale options from 132 kV system to 400 kV system. Key features: fault level verification of switchgear, models acceptable to STU and CTUIL and reports for GNA/connectivity application. Suited to BESS integrators, renewable developers seeking connectivity and utilities and consultants. Delivered in line with CEA (Technical Standards for Connectivity) Regulations, Indian Electricity Grid Code and IEEE 1547. Mobilisation Kick-off in 1 week; serves South India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Satpura
- Model
- SAT-4C2 series
- Listing type
- Service
- Unit
- report
- Minimum order
- 1 report
- Lead time
- Kick-off in 1 week
- Warranty
- Clarifications to utility at no cost
- Standards
- CEA (Technical Standards for Connectivity) Regulations, Indian Electricity Grid Code, IEEE 1547
- Delivers to
- South India
- GST rate
- 18 %
- Country of origin
- India (imported sub-assemblies)
- Delivery terms
- Site mobilisation as per work order
- Returns
- Re-work of defective scope at no cost
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Network scale132 kV systemSAT-4C2-01 | Network scale: 132 kV system | 1 report · Kick-off in 1 week | on quote |
| Network scale220 kV systemSAT-4C2-02 | Network scale: 220 kV system | 1 report · Kick-off in 1 week | on quote |
| Network scale400 kV systemSAT-4C2-03 | Network scale: 400 kV system | 1 report · Kick-off in 1 week | on quote |
Specifications
| Network scale | 132 kV system to 400 kV system (see variants) |
|---|---|
| Study type | Harmonics |
| Software | DIgSILENT PowerFactory |
| Model data | Utility network modelmade to order: Client single line diagram and data |
| Deliverables | Model files and relay settings |
| Grid code checks | LVRT/HVRT and ramp rate |
| Review | Utility submission supportmade to order: Lender review |
| Scenarios | Multiple dispatch cases |
| Team | Power system engineer |
| Turnaround | 4-6 weeksmade to order: 2-3 weeks |
| Validation | Peer review |