Catalogue / Power system studies (load flow, short circuit, grid code)

No photo yet

Harmonic and power quality study, Titan seriesSample

by Satpurapushpak Projects (Sample) · verified by BARREL

Price on quote

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Satpurapushpak Projects (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

The Titan service of harmonic and power quality study by Satpurapushpak covers 6 network scale options (11 kV plant to 400 kV system). Design: reports for GNA/connectivity application, PSS/E and PSCAD model support and relay setting files ready to load. Suited to utilities and consultants, BESS integrators and renewable developers seeking connectivity. Delivered in line with CEA (Technical Standards for Connectivity) Regulations, Indian Electricity Grid Code and IEEE 1547. Mobilisation 2-6 weeks; serves All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Satpurapushpak
Model
SAT-4B2 series
Listing type
Service
Unit
report
Minimum order
1 report
Lead time
2-6 weeks
Warranty
Clarifications to utility at no cost
Standards
CEA (Technical Standards for Connectivity) Regulations, Indian Electricity Grid Code, IEEE 1547
Delivers to
All India and export (SAARC, Middle East, Africa)
GST rate
18 %
Country of origin
India
Delivery terms
Site mobilisation as per work order
Returns
Re-work of defective scope at no cost
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Network scale11 kV plantSAT-4B2-01Network scale: 11 kV plant1 report · 2-6 weekson quote
Network scale33 kV plantSAT-4B2-02Network scale: 33 kV plant1 report · 2-6 weekson quote
Network scale66 kV systemSAT-4B2-03Network scale: 66 kV system1 report · 2-6 weekson quote
Network scale132 kV systemSAT-4B2-04Network scale: 132 kV system1 report · 2-6 weekson quote
Network scale220 kV systemSAT-4B2-05Network scale: 220 kV system1 report · 2-6 weekson quote
Network scale400 kV systemSAT-4B2-06Network scale: 400 kV system1 report · 2-6 weekson quote

Specifications

Network scale11 kV plant to 400 kV system (see variants)
Study typeProtection coordination
SoftwarePSS/E
Model dataUtility network modelmade to order: Client single line diagram and data
DeliverablesModel files and relay settings
Grid code checksLVRT/HVRT and ramp ratemade to order: Voltage and reactive power capability
ReviewLender review
ScenariosNormal and N-1made to order: Multiple dispatch cases
TeamLead plus modelling specialistmade to order: Power system engineer
Turnaround2-3 weeks
ValidationPeer reviewmade to order: Compared with measured data

BARREL: Bharat Atom Renewable Resources Energy Limited