Saurashtra Ultra 7 manual changeover switch, offered in 5 rating options from 63 A to 630 A. Design: mechanical and electrical interlock prevents paralleling sources, programmable voltage and frequency sensing and manual override for maintenance. Typically used for commercial buildings with DG sets, hospitals and data centres and solar-genset hybrid sites. Designed and tested to IEC 60947-6-1, IS/IEC 60947-3 and IS 8623 (Part 1). Lead time 4-6 weeks; delivers to All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Saurashtra
- Model
- SAU-2B1 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 1 nos
- Lead time
- 4-6 weeks
- Warranty
- 12 months from commissioning
- Standards
- IEC 60947-6-1, IS/IEC 60947-3, IS 8623 (Part 1)
- Delivers to
- All India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Corrugated box on pallet
- Delivery terms
- FOR nearest railhead
- Returns
- Returns within 15 days if unused, in original packing
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Rating63 ASAU-2B1-01 | Rating: 63 A | 1 nos · 4-6 weeks | for verified buyers |
| Rating125 ASAU-2B1-02 | Rating: 125 A | 1 nos · 4-6 weeks | for verified buyers |
| Rating250 ASAU-2B1-03 | Rating: 250 A | 1 nos · 4-6 weeks | for verified buyers |
| Rating400 ASAU-2B1-04 | Rating: 400 A | 1 nos · 4-6 weeks | for verified buyers |
| Rating630 ASAU-2B1-05 | Rating: 630 A | 1 nos · 4-6 weeks | for verified buyers |
Specifications
| Rating | 63 A to 630 A (see variants) |
|---|---|
| Type | Manual changeovermade to order: Motorised changeover / ATS panel |
| Poles | 4P |
| Rated voltage | 415 V AC |
| Transfer device | Contactor pair |
| Transition | Openmade to order: Closed / Delayed |
| Controller | Microprocessor ATS controller |
| Transfer time | Under 10 smade to order: Under 3 s |
| Mains failure delay | Adjustable 0-60 s |
| Short-circuit withstand | 25 kAmade to order: 10 kA / 36 kA / 50 kA |
| Enclosure | IP54 sheet steel |
| Auxiliary supply | 24 V DCmade to order: 230 V AC |
| Genset start signal | Potential-free contact |