Distributed control system (DCS) controller, Plus seriesSample
by Shaktiline Instruments (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Shaktiline Instruments (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Distributed control system (DCS) controller from Shaktiline, Plus series: 4 i/O points options between 128 I/O and 1024 I/O. Highlights: programming with standard IEC 61131-3 languages, onboard diagnostics and web server and firmware with cyber-security hardening. Typically used for power plant balance-of-plant control, boiler and turbine auxiliaries and water treatment and utilities. Designed and tested to IEC 61131-2, IEC 61131-3 and IEC 61508 (SIL 2/3). Lead time 8-12 weeks; delivers to North India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Shaktiline
- Model
- SHA-A39 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 5 nos
- Lead time
- 8-12 weeks
- Warranty
- 12 months from commissioning
- Standards
- IEC 61131-2, IEC 61131-3, IEC 61508 (SIL 2/3)
- Delivers to
- North India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- As per item, transit-safe
- Delivery terms
- FOR nearest railhead
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| I/O points128 I/OSHA-A39-01 | I/O points: 128 I/O | 5 nos · 8-12 weeks | for verified buyers |
| I/O points256 I/OSHA-A39-02 | I/O points: 256 I/O | 5 nos · 8-12 weeks | for verified buyers |
| I/O points512 I/OSHA-A39-03 | I/O points: 512 I/O | 5 nos · 8-12 weeks | for verified buyers |
| I/O points1024 I/OSHA-A39-04 | I/O points: 1024 I/O | 5 nos · 8-12 weeks | for verified buyers |
Specifications
| I/O points | 128 I/O to 1024 I/O (see variants) |
|---|---|
| CPU memory | 8 MB |
| Scan time | < 0.1 ms per 1k |
| Redundancy | Hot standby CPU and network |
| Programming | IEC 61131-3 (LD, FBD, ST) |
| Communication | Profinetmade to order: Modbus TCP / Ethernet/IP / Profibus DP |
| Digital input | 24 VDC sink/source |
| Analog input | 4-20 mA HART |
| Power supply | 110-230 VACmade to order: 24 VDC |
| Operating temperature | -25 to 70 °Cmade to order: 0 to 60 °C |
| Hot swap | Yes, I/O modules |
| Security | Password + access control, firmware signing |