Catalogue / Electrical safety audits
Fire and arc-flash risk assessment, Ultra seriesSample
by Shaktimark Projects (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Shaktimark Projects (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Shaktimark Ultra fire and arc-flash risk assessment, offered in 4 installed load options from 5 MVA to 50 MVA. Design: risk-ranked findings, fire exit and detection checks and compliance matrix against CEA safety rules. Suited to solar and wind sites, manufacturing plants and data centres. Delivered in line with Indian Electricity Act 2003, CEA (Measures relating to Safety) Regulations and IS 5216. Mobilisation Report in 7-14 days; serves South India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Shaktimark
- Model
- SHA-2D5 series
- Listing type
- Service
- Unit
- site
- Minimum order
- 1 site
- Lead time
- Report in 7-14 days
- Warranty
- Clarifications on report at no cost for 6 months
- Standards
- Indian Electricity Act 2003, CEA (Measures relating to Safety) Regulations, IS 5216
- Delivers to
- South India
- GST rate
- 18 %
- Country of origin
- India
- Delivery terms
- Site mobilisation as per work order
- Returns
- Re-work of defective scope at no cost
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Installed load5 MVASHA-2D5-01 | Installed load: 5 MVA | 1 site · Report in 7-14 days | for verified buyers |
| Installed load10 MVASHA-2D5-02 | Installed load: 10 MVA | 1 site · Report in 7-14 days | for verified buyers |
| Installed load25 MVASHA-2D5-03 | Installed load: 25 MVA | 1 site · Report in 7-14 days | for verified buyers |
| Installed load50 MVASHA-2D5-04 | Installed load: 50 MVA | 1 site · Report in 7-14 days | for verified buyers |
Specifications
| Installed load | 5 MVA to 50 MVA (see variants) |
|---|---|
| Scope | Audit with measurements |
| Auditor | Chartered engineermade to order: CEA-licensed engineer |
| Measurements | Earth resistance, insulation |
| Report | Findings with risk ratingmade to order: Action plan with timeline |
| Statutory records | Permit-to-work audit |
| Sampling | 100% of HV equipment |
| Follow-up | Close-out verificationmade to order: Re-audit after 3 months |
| Turnaround | 1-2 weeksmade to order: 3-4 weeks |
| Presentation | Findings to managementmade to order: Report only |
| Accreditation | Government recognised agency |