Catalogue / Substation & line O&M
Transmission line patrolling and maintenance, Xtra 6 seriesSample
by Shaktitek Infra Services (Sample) · verified by BARREL
Price on quote
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Shaktitek Infra Services (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Transmission line patrolling and maintenance from Shaktitek, Xtra 6 series: 5 voltage level options between 33 kV and 400 kV. Design: outage planning with the utility, permit-to-work and lockout-tagout and oil leak and silica gel checks. Used by renewable pooling substations, railway and metro sub-stations and state utility outsourcing. Delivered in line with CEA (Measures relating to Safety) Regulations, CEA (Grid Standards) Regulations and IS 10028 (Transformer Installation). Mobilisation Baseline condition audit first; serves East & North-East India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Shaktitek
- Model
- SHA-727 series
- Listing type
- Service
- Unit
- month
- Minimum order
- 1 month
- Lead time
- Baseline condition audit first
- Warranty
- Service credits for avoidable outages
- Standards
- CEA (Measures relating to Safety) Regulations, CEA (Grid Standards) Regulations, IS 10028 (Transformer Installation)
- Delivers to
- East & North-East India
- GST rate
- 18 %
- Country of origin
- India (imported sub-assemblies)
- Delivery terms
- Site mobilisation as per work order
- Returns
- Re-work of defective scope at no cost
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Voltage level33 kVSHA-727-01 | Voltage level: 33 kV | 1 month · Baseline condition audit first | on quote |
| Voltage level66 kVSHA-727-02 | Voltage level: 66 kV | 1 month · Baseline condition audit first | on quote |
| Voltage level132 kVSHA-727-03 | Voltage level: 132 kV | 1 month · Baseline condition audit first | on quote |
| Voltage level220 kVSHA-727-04 | Voltage level: 220 kV | 1 month · Baseline condition audit first | on quote |
| Voltage level400 kVSHA-727-05 | Voltage level: 400 kV | 1 month · Baseline condition audit first | on quote |
Specifications
| Voltage level | 33 kV to 400 kV (see variants) |
|---|---|
| Scope | Operation, maintenance and statutory compliancemade to order: Operation and maintenance / Maintenance only |
| Shift pattern | 3 shifts, 24x7 |
| Manpower | Engineer plus 6 operators |
| Line patrolling | Monthly foot patrolmade to order: Quarterly drone patrol |
| Testing | Annual relay and CT/PT test |
| Statutory records | Log books, permits, shutdown registermade to order: CEIG renewal support |
| Spares | Consumables includedmade to order: Critical spares by owner |
| Response time | 4 hoursmade to order: 2 hours for trip |
| Reporting | Real-time dashboards |
| Term | 3 yearsmade to order: 1 year |