Catalogue / Gas & water analysers
Turbidity analyser, Core seriesSample
by Shivalik Instruments (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Shivalik Instruments (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Shivalik Core turbidity analyser, offered in 4 parameter options from Conductivity to Silica. Design: HART or Modbus interface for DCS, automatic calibration and cleaning option and online continuous measurement with alarm relays. Suited to cooling water treatment, boiler water and steam cycle chemistry and effluent and demineralisation plants. Designed and tested to IEC 61207, IS 3025 and IEC 60079-0. Lead time 8-12 weeks; delivers to All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Shivalik
- Model
- SHI-916 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 1 nos
- Lead time
- 8-12 weeks
- Warranty
- 12 months from commissioning
- Standards
- IEC 61207, IS 3025, IEC 60079-0
- Delivers to
- All India and export (SAARC, Middle East, Africa)
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- As per item, transit-safe
- Delivery terms
- Ex-works, freight extra at actuals
- Returns
- No returns on made-to-order items
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| ParameterConductivitySHI-916-01 | Parameter: Conductivity | 1 nos · 8-12 weeks | for verified buyers |
| ParameterDissolved oxygenSHI-916-02 | Parameter: Dissolved oxygen | 1 nos · 8-12 weeks | for verified buyers |
| ParameterTurbiditySHI-916-03 | Parameter: Turbidity | 1 nos · 8-12 weeks | for verified buyers |
| ParameterSilicaSHI-916-04 | Parameter: Silica | 1 nos · 8-12 weeks | for verified buyers |
Specifications
| Parameter | Conductivity to Silica (see variants) |
|---|---|
| Measurement range | pH 0-14 |
| Accuracy | ±0.01 pH |
| Output | RS-485 Modbusmade to order: 4-20 mA / Relay alarm |
| Sample flow | 100-500 mL/min |
| Power supply | 24 VDC |
| Enclosure | IP66 wall-mountmade to order: IP65 |
| Calibration | Automatic |
| Sensor life | 12-24 months |
| Response time | < 30 s |
| Hazardous area | Ex dmade to order: Non-hazardous |
| Display | Graphic colour LCD |