Numerical overcurrent and earth fault relay, Neo 9 seriesSample
by Shivalik Protection Systems (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Shivalik Protection Systems (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Numerical overcurrent and earth fault relay from Shivalik, Neo 9 series: 4 function options between Feeder protection and Busbar differential. Design: front USB and rear Ethernet ports, self-supervision with watchdog and graphical logic programming. Suited to solar plant collector feeders, industrial incomers and substation feeders. Designed and tested to IEC 60255, IEC 61850 and IS 3231. Lead time 8-10 weeks; delivers to All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Shivalik
- Model
- SHI-9A6 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 5 nos
- Lead time
- 8-10 weeks
- Warranty
- 24 months
- Standards
- IEC 60255, IEC 61850, IS 3231
- Delivers to
- All India
- GST rate
- 18 %
- Country of origin
- India (imported sub-assemblies)
- Packaging
- Wooden crate, seaworthy
- Delivery terms
- FOR nearest railhead
- Returns
- No returns on made-to-order items
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| FunctionFeeder protectionSHI-9A6-01 | Function: Feeder protection | 5 nos · 8-10 weeks | for verified buyers |
| FunctionTransformer differentialSHI-9A6-02 | Function: Transformer differential | 5 nos · 8-10 weeks | for verified buyers |
| FunctionLine distanceSHI-9A6-03 | Function: Line distance | 5 nos · 8-10 weeks | for verified buyers |
| FunctionBusbar differentialSHI-9A6-04 | Function: Busbar differential | 5 nos · 8-10 weeks | for verified buyers |
Specifications
| Function | Feeder protection to Busbar differential (see variants) |
|---|---|
| Aux supply | 220 V DCmade to order: 24-250 V DC / 110 V DC |
| CT input | 1/5 A selectable |
| VT input | 63.5 Vmade to order: 110 V |
| Binary inputs | 16 |
| Output relays | 12made to order: 6 / 24 |
| Communication | Modbusmade to order: IEC 61850 Ed 2 / IEC 60870-5-103 |
| Display | LCD with keypad |
| Disturbance recorder | Up to 20 recordsmade to order: Up to 100 records |
| Accuracy class | Class 0.5 metering |
| Case | Draw-outmade to order: Flush mount |
| Time sync | IRIG-B |
| Cyber-security | Role-based access |