Catalogue / Power system studies (load flow, short circuit, grid code)

No photo yet

Load flow and short-circuit study, Titan 8 seriesSample

by Tamraline Infra Services (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Tamraline Infra Services (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

The Titan 8 service of load flow and short-circuit study by Tamraline covers 3 network scale options (33 kV plant to 132 kV system). Design: relay setting files ready to load, reactive power capability curves and reports for GNA/connectivity application. Typically used for renewable developers seeking connectivity, industrial plants adding generation and BESS integrators. Delivered in line with CEA (Technical Standards for Connectivity) Regulations, Indian Electricity Grid Code and IEEE 1547. Mobilisation 2-6 weeks; serves West India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Tamraline
Model
TAM-467 series
Listing type
Service
Unit
report
Minimum order
1 report
Lead time
2-6 weeks
Warranty
Revision for utility comments
Standards
CEA (Technical Standards for Connectivity) Regulations, Indian Electricity Grid Code, IEEE 1547
Delivers to
West India
GST rate
18 %
Country of origin
India (imported sub-assemblies)
Delivery terms
Site mobilisation as per work order
Returns
Re-work of defective scope at no cost
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Network scale33 kV plantTAM-467-01Network scale: 33 kV plant1 report · 2-6 weeksfor verified buyers
Network scale66 kV systemTAM-467-02Network scale: 66 kV system1 report · 2-6 weeksfor verified buyers
Network scale132 kV systemTAM-467-03Network scale: 132 kV system1 report · 2-6 weeksfor verified buyers

Specifications

Network scale33 kV plant to 132 kV system (see variants)
Study typeLoad flow and short circuit
SoftwareDIgSILENT PowerFactory
Model dataUtility network modelmade to order: Client single line diagram and data
DeliverablesModel files and relay settings
Grid code checksLVRT/HVRT and ramp ratemade to order: Voltage and reactive power capability
ReviewLender reviewmade to order: Utility submission support
ScenariosMultiple dispatch cases
TeamPower system engineermade to order: Lead plus modelling specialist
Turnaround2-3 weeks
ValidationPeer review