Mobile GIS substation from Tamratek, Max series: 4 transformer rating options between 20 MVA and 63 MVA. Design: compact oil spill containment, quick restoration after transformer failure and bay-extension and maintenance outage cover. Typically used for event power supply, temporary construction power and maintenance outage support. Designed and tested to IEC 62271-202, IS 2026 and IEC 60076. Lead time 16-24 weeks; delivers to All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Tamratek
- Model
- TAM-7D6 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 1 nos
- Lead time
- 16-24 weeks
- Warranty
- 36 months
- Standards
- IEC 62271-202, IS 2026, IEC 60076
- Delivers to
- All India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Wooden crate, seaworthy
- Delivery terms
- Ex-works, freight extra at actuals
- Returns
- Returns within 15 days if unused, in original packing
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Transformer rating20 MVATAM-7D6-01 | Transformer rating: 20 MVA | 1 nos · 16-24 weeks | for verified buyers |
| Transformer rating31.5 MVATAM-7D6-02 | Transformer rating: 31.5 MVA | 1 nos · 16-24 weeks | for verified buyers |
| Transformer rating50 MVATAM-7D6-03 | Transformer rating: 50 MVA | 1 nos · 30-40 weeks | for verified buyers |
| Transformer rating63 MVATAM-7D6-04 | Transformer rating: 63 MVA | 1 nos · 30-40 weeks | for verified buyers |
Specifications
| Transformer rating | 20 MVA to 63 MVA (see variants) |
|---|---|
| Primary voltage | 220 kVmade to order: 33 kV / 66 kV / 132 kV |
| Secondary voltage | 11 kVmade to order: 33 kV |
| Chassis | Low-bed trailermade to order: Skid / Container |
| Primary switchgear | GIS baymade to order: AIS disconnector and breaker |
| Secondary switchgear | Indoor VCB panel |
| Control and relay | Numerical relays |
| Fire protection | Detection and extinguisher |
| Auxiliary supply | DC battery + DG |
| Transport weight | Up to 45 t |
| Setup time | < 4 hoursmade to order: < 24 hours |
| Grounding | Mobile earthing kit |
| Cable reel | Included |