Catalogue / Gas & water analysers
Dissolved oxygen analyser, Elite 7 seriesSample
by Taxilagaruda Controls (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Taxilagaruda Controls (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Dissolved oxygen analyser from Taxilagaruda, Elite 7 series: 4 parameter options between Dissolved oxygen and Flue gas O2. Design: compact wall-mount enclosure, diagnostics for sensor health and sample conditioning panel supplied. Used by effluent and demineralisation plants, stack emission monitoring and cooling water treatment. Designed and tested to IEC 61207, IS 3025 and IEC 60079-0. Lead time 3-5 weeks; delivers to All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Taxilagaruda
- Model
- TAX-297 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 1 nos
- Lead time
- 3-5 weeks
- Warranty
- 12 months from commissioning
- Standards
- IEC 61207, IS 3025, IEC 60079-0
- Delivers to
- All India and export (SAARC, Middle East, Africa)
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- As per item, transit-safe
- Delivery terms
- FOR nearest railhead
- Returns
- Returns within 15 days if unused, in original packing
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| ParameterDissolved oxygenTAX-297-01 | Parameter: Dissolved oxygen | 1 nos · 3-5 weeks | for verified buyers |
| ParameterTurbidityTAX-297-02 | Parameter: Turbidity | 1 nos · 3-5 weeks | for verified buyers |
| ParameterSilicaTAX-297-03 | Parameter: Silica | 1 nos · 8-12 weeks | for verified buyers |
| ParameterFlue gas O2TAX-297-04 | Parameter: Flue gas O2 | 1 nos · 8-12 weeks | for verified buyers |
Specifications
| Parameter | Dissolved oxygen to Flue gas O2 (see variants) |
|---|---|
| Measurement range | 0-1000 ppbmade to order: pH 0-14 / 0-2000 µS/cm / 0-20 mg/L |
| Accuracy | ±1% of readingmade to order: ±0.01 pH |
| Output | RS-485 Modbusmade to order: 4-20 mA / Relay alarm |
| Sample flow | 100-500 mL/min |
| Power supply | 230 VAC |
| Enclosure | IP65 |
| Calibration | Two-point manualmade to order: Automatic |
| Sensor life | 12-24 months |
| Response time | T90 < 10 s |
| Hazardous area | Ex d |
| Display | Graphic colour LCD |