Numerical overcurrent and earth fault relay, Volt 4 seriesSample
by Taxila Protection Systems (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Taxila Protection Systems (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
The Volt 4 range of numerical overcurrent and earth fault relay by Taxila covers 5 function options (Overcurrent / earth fault to Line distance). Design: event and fault recorder with 1 ms stamps, self-supervision with watchdog and breaker failure and trip circuit supervision. Suited to solar plant collector feeders, industrial incomers and transformer bays. Designed and tested to IEC 60255, IEC 61850 and IS 3231. Lead time 3-6 weeks; delivers to West India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Taxila
- Model
- TAX-9A5 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 2 nos
- Lead time
- 3-6 weeks
- Warranty
- 24 months
- Standards
- IEC 60255, IEC 61850, IS 3231
- Delivers to
- West India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Steel skid with shrink wrap
- Delivery terms
- Ex-works, freight extra at actuals
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| FunctionOvercurrent / earth faultTAX-9A5-01 | Function: Overcurrent / earth fault | 2 nos · 3-6 weeks | for verified buyers |
| FunctionMotor protectionTAX-9A5-02 | Function: Motor protection | 2 nos · 3-6 weeks | for verified buyers |
| FunctionFeeder protectionTAX-9A5-03 | Function: Feeder protection | 2 nos · 3-6 weeks | for verified buyers |
| FunctionTransformer differentialTAX-9A5-04 | Function: Transformer differential | 2 nos · 8-10 weeks | for verified buyers |
| FunctionLine distanceTAX-9A5-05 | Function: Line distance | 2 nos · 8-10 weeks | for verified buyers |
Specifications
| Function | Overcurrent / earth fault to Line distance (see variants) |
|---|---|
| Aux supply | 220 V DCmade to order: 24-250 V DC / 110 V DC |
| CT input | 5 Amade to order: 1 A / 1/5 A selectable |
| VT input | 110 Vmade to order: 63.5 V |
| Binary inputs | 32 |
| Output relays | 12 |
| Communication | IEC 60870-5-103 |
| Display | LCD with keypad |
| Disturbance recorder | Up to 100 recordsmade to order: Up to 20 records |
| Accuracy class | Class 0.5 metering |
| Case | Draw-outmade to order: Flush mount |
| Time sync | IRIG-Bmade to order: SNTP / PTP |
| Cyber-security | Role-based access |