Catalogue / Contact & messenger wires
Grooved copper contact wire, Core seriesSample
by Taxila Traction Systems (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Taxila Traction Systems (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
The Core range of grooved copper contact wire by Taxila covers 5 conductor options (107 mm2 contact wire to Droppers). Key features: high wear resistance, low resistivity and uniform profile for pantograph. Used by metro rail, industrial sidings and indian Railways. Designed and tested to RDSO Spec ETI/OHE, IS 8130 and IS 613. Lead time 4-6 weeks; delivers to All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Taxila
- Model
- TAX-7B3 series
- Listing type
- Product
- Unit
- km
- Minimum order
- 2 km
- Lead time
- 4-6 weeks
- Warranty
- 12 months
- Standards
- RDSO Spec ETI/OHE, IS 8130, IS 613
- Delivers to
- All India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Corrugated box on pallet
- Delivery terms
- FOR nearest railhead
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Conductor107 mm2 contact wireTAX-7B3-01 | Conductor: 107 mm2 contact wire | 2 km · 4-6 weeks | for verified buyers |
| Conductor150 mm2 contact wireTAX-7B3-02 | Conductor: 150 mm2 contact wire | 2 km · 4-6 weeks | for verified buyers |
| Conductor65 mm2 messengerTAX-7B3-03 | Conductor: 65 mm2 messenger | 2 km · 4-6 weeks | for verified buyers |
| Conductor95 mm2 messengerTAX-7B3-04 | Conductor: 95 mm2 messenger | 2 km · 8-10 weeks | for verified buyers |
| ConductorDroppersTAX-7B3-05 | Conductor: Droppers | 2 km · 8-10 weeks | for verified buyers |
Specifications
| Conductor | 107 mm2 contact wire to Droppers (see variants) |
|---|---|
| Material | Copper silvermade to order: Hard drawn copper / Cadmium copper / Copper magnesium |
| Section | Grooved |
| Tensile strength | ≥ 345 N/mm2made to order: ≥ 480 N/mm2 |
| Conductivity | ≥ 97% IACSmade to order: ≥ 80% IACS |
| Stranding | 7/3.5 |
| Drum length | 3000 mmade to order: 2000 m |
| Wear allowance | 20% |
| Surface | Grooved |
| Stagger | As per RDSO |
| Tolerance | +/- 2% dimensions |
| Packing | Wooden drum |
| Test | Tensile, bend, resistivity |