Catalogue / Fire detection & alarm
Manual call point (MCP) and hooter, Neo 7 seriesSample
by Teestavajra Fire Engineers (Sample) · verified by BARREL
Price on quote
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Teestavajra Fire Engineers (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Manual call point (MCP) and hooter from Teestavajra, Neo 7 series: 4 panel loops / zones options between 1 loop addressable (250 pts) and 8 loop addressable. Design: battery charger with supervision, event history with time and date and cause-and-effect programming. Used by battery rooms and BESS containers, control rooms and relay panel rooms and offices and warehouses. Designed and tested to IS 2189, EN 54-2 and EN 54-4. Lead time 2-3 weeks; delivers to All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Teestavajra
- Model
- TEE-232 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 2 nos
- Lead time
- 2-3 weeks
- Warranty
- 12 months from commissioning
- Standards
- IS 2189, EN 54-2, EN 54-4
- Delivers to
- All India and export (SAARC, Middle East, Africa)
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Corrugated box on pallet
- Delivery terms
- Ex-works, freight extra at actuals
- Returns
- Returns within 15 days if unused, in original packing
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Panel loops / zones1 loop addressable (250 pts)TEE-232-01 | Panel loops / zones: 1 loop addressable (250 pts) | 2 nos · 2-3 weeks | on quote |
| Panel loops / zones2 loop addressableTEE-232-02 | Panel loops / zones: 2 loop addressable | 2 nos · 2-3 weeks | on quote |
| Panel loops / zones4 loop addressableTEE-232-03 | Panel loops / zones: 4 loop addressable | 2 nos · 4-6 weeks | on quote |
| Panel loops / zones8 loop addressableTEE-232-04 | Panel loops / zones: 8 loop addressable | 2 nos · 4-6 weeks | on quote |
Specifications
| Panel loops / zones | 1 loop addressable (250 pts) to 8 loop addressable (see variants) |
|---|---|
| Panel type | Conventionalmade to order: Addressable (analogue) |
| Loop capacity | 127 devicesmade to order: 250 devices per loop |
| Display | Alphanumeric LCD |
| Network | Up to 32 panels |
| Power supply | 230 VAC with 24 V battery backup |
| Battery backup | 24 h standby + 30 min alarm |
| Outputs | Sounder circuits, relay outputs |
| Communication | RS-485made to order: Ethernet / Modbus to BMS |
| Enclosure | Steel IP30made to order: IP54 |
| Detector types | Heat |
| Event log | 10,000 events |