Catalogue / Rack PDUs & busway
Basic vertical rack PDU, Elite seriesSample
by Thanjavurdhruv Critical Power (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Thanjavurdhruv Critical Power (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Thanjavurdhruv Elite basic vertical rack PDU, offered in 4 current options from 250 A to 800 A. Design: locking IEC C13/C19 outlets prevent accidental unplugging, per-outlet metering and switching on intelligent models and tool-less 0U vertical mounting. Suited to server rooms, colocation halls and data centre racks. Designed and tested to IEC 62368-1, IEC 60320 and IEC 61439-6. Lead time 2-3 weeks; delivers to All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Thanjavurdhruv
- Model
- THA-2B4 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 1 nos
- Lead time
- 2-3 weeks
- Warranty
- 12 months from supply
- Standards
- IEC 62368-1, IEC 60320, IEC 61439-6
- Delivers to
- All India and export (SAARC, Middle East, Africa)
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Steel skid with shrink wrap
- Delivery terms
- FOR nearest railhead
- Returns
- Returns within 15 days if unused, in original packing
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Current250 ATHA-2B4-01 | Current: 250 A | 1 nos · 2-3 weeks | for verified buyers |
| Current400 ATHA-2B4-02 | Current: 400 A | 1 nos · 2-3 weeks | for verified buyers |
| Current630 ATHA-2B4-03 | Current: 630 A | 1 nos · 4-6 weeks | for verified buyers |
| Current800 ATHA-2B4-04 | Current: 800 A | 1 nos · 4-6 weeks | for verified buyers |
Specifications
| Current | 250 A to 800 A (see variants) |
|---|---|
| Type | Monitored by outlet |
| Phase | 1-phase |
| Outlets | 24 x C13made to order: 12 x C13 / 20 x C13 + 4 x C19 / 42 x C13 |
| Voltage | 400 Vmade to order: 230 V / 415 V |
| Mounting | Vertical 0U |
| Input plug | IEC 60309made to order: Hard-wired |
| Metering accuracy | 1%made to order: 0.5% |
| Network | Modbusmade to order: SNMP / Ethernet |
| Busway rating | Up to 800 A |
| Sensors | Temperaturemade to order: Humidity |
| Breakers | Per-phase MCBmade to order: Per-outlet MCB |
| Cord length | 2 m |