Catalogue / Fire detection & alarm

No photo yet

Manual call point (MCP) and hooter, Plus seriesSample

by Thanjavurkiran Fire Engineers (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Thanjavurkiran Fire Engineers (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

Thanjavurkiran Plus manual call point (MCP) and hooter, offered in 5 panel loops / zones options from 8 zones conventional to 8 loop addressable. Design: walk-test mode for commissioning, connect to BMS and SCADA and loop short-circuit isolators on every loop. Suited to offices and warehouses, battery rooms and BESS containers and control rooms and relay panel rooms. Designed and tested to IS 2189, EN 54-2 and EN 54-4. Lead time 2-3 weeks; delivers to West India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Thanjavurkiran
Model
THA-237 series
Listing type
Product
Unit
nos
Minimum order
5 nos
Lead time
2-3 weeks
Warranty
12 months from commissioning
Standards
IS 2189, EN 54-2, EN 54-4
Delivers to
West India
GST rate
18 %
Country of origin
India
Packaging
Corrugated box on pallet
Delivery terms
Ex-works, freight extra at actuals
Returns
Returns within 15 days if unused, in original packing
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Panel loops / zones8 zones conventionalTHA-237-01Panel loops / zones: 8 zones conventional5 nos · 2-3 weeksfor verified buyers
Panel loops / zones1 loop addressable (250 pts)THA-237-02Panel loops / zones: 1 loop addressable (250 pts)5 nos · 2-3 weeksfor verified buyers
Panel loops / zones2 loop addressableTHA-237-03Panel loops / zones: 2 loop addressable5 nos · 2-3 weeksfor verified buyers
Panel loops / zones4 loop addressableTHA-237-04Panel loops / zones: 4 loop addressable5 nos · 4-6 weeksfor verified buyers
Panel loops / zones8 loop addressableTHA-237-05Panel loops / zones: 8 loop addressable5 nos · 4-6 weeksfor verified buyers

Specifications

Panel loops / zones8 zones conventional to 8 loop addressable (see variants)
Panel typeConventionalmade to order: Addressable (analogue)
Loop capacity127 devices
DisplayAlphanumeric LCD
NetworkUp to 32 panels
Power supply230 VAC with 24 V battery backup
Battery backup24 h standby + 30 min alarm
OutputsSounder circuits, relay outputs
CommunicationRS-485made to order: Ethernet / Modbus to BMS
EnclosureIP54
Detector typesSmoke
Event log10,000 events

BARREL: Bharat Atom Renewable Resources Energy Limited