Catalogue / Transformer NIFPS

No photo yet

Drain-and-stir transformer fire protection system, Volt 9 seriesSample

by Thanjavurkiran Fire Engineers (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Thanjavurkiran Fire Engineers (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

The Volt 9 range of drain-and-stir transformer fire protection system by Thanjavurkiran covers 3 transformer oil volume options (20-40 kL to 60-100 kL). Design: fully automatic with manual override, nitrogen blankets and cools oil to extinguish fire and control cubicle with status indication to SCADA. Suited to generator transformers at plants, reactors in EHV yards and renewable plant pooling transformers. Designed and tested to IS 3034, CBIP Manual on Transformers and CEA Safety Regulations 2023. Lead time 8-10 weeks; delivers to West India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Thanjavurkiran
Model
THA-C13 series
Listing type
Product
Unit
set
Minimum order
5 set
Lead time
8-10 weeks
Warranty
24 months from commissioning
Standards
IS 3034, CBIP Manual on Transformers, CEA Safety Regulations 2023
Delivers to
West India
GST rate
18 %
Country of origin
India
Packaging
Steel skid with shrink wrap
Delivery terms
Ex-works, freight extra at actuals
Returns
Replacement of items damaged in transit within 7 days
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Transformer oil volume20-40 kLTHA-C13-01Transformer oil volume: 20-40 kL5 set · 8-10 weeksfor verified buyers
Transformer oil volume40-60 kLTHA-C13-02Transformer oil volume: 40-60 kL5 set · 8-10 weeksfor verified buyers
Transformer oil volume60-100 kLTHA-C13-03Transformer oil volume: 60-100 kL5 set · 8-10 weeksfor verified buyers

Specifications

Transformer oil volume20-40 kL to 60-100 kL (see variants)
PrincipleNitrogen injection and drain
Nitrogen cylinders5 x 68 Lmade to order: 3 x 68 L / 8 x 68 L
Operating pressure150 bar
Oil drain valvePneumatic
DetectionDifferential relay + Buchholz + heat detector
ControlPLC-based cubicle with hot standby
Response timeWithin 30 seconds
Oil drain depthTop 10% of the tank oil
Power supply24 VDC with backup batterymade to order: 110 VDC
Ex-ventIncluded
CommunicationHardwired to SCADAmade to order: IEC 60870-5-104
IsolationCable gland and cubicle IP55