Catalogue / Compact secondary substations
Package substation for solar plant, Neo seriesSample
by Thanjavurprakash Transformer Works (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Thanjavurprakash Transformer Works (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Package substation for solar plant from Thanjavurprakash, Neo series: 3 transformer rating options between 630 kVA and 1600 kVA. Highlights: oil sump and fire barriers, factory assembled and tested and heat dissipation tested. Used by urban distribution, housing complexes and telecom and metro. Designed and tested to IEC 62271-202, IS 1180 and IEC 62271-200. Lead time 10-14 weeks; delivers to All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Thanjavurprakash
- Model
- THA-322 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 2 nos
- Lead time
- 10-14 weeks
- Warranty
- 18 months
- Standards
- IEC 62271-202, IS 1180, IEC 62271-200
- Delivers to
- All India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Steel skid with shrink wrap
- Delivery terms
- FOR nearest railhead
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Transformer rating630 kVATHA-322-01 | Transformer rating: 630 kVA | 2 nos · 10-14 weeks | for verified buyers |
| Transformer rating1000 kVATHA-322-02 | Transformer rating: 1000 kVA | 2 nos · 10-14 weeks | for verified buyers |
| Transformer rating1600 kVATHA-322-03 | Transformer rating: 1600 kVA | 2 nos · 10-14 weeks | for verified buyers |
Specifications
| Transformer rating | 630 kVA to 1600 kVA (see variants) |
|---|---|
| Primary voltage | 22 kVmade to order: 11 kV / 33 kV |
| Secondary voltage | 0.69 kVmade to order: 0.433 kV |
| HV equipment | Ring main unit |
| Transformer type | Cast resin dry |
| LT section | MCCB feeders |
| Enclosure | FRPmade to order: Galvanised steel / Concrete |
| Ingress protection | IP54 |
| Internal arc rating | 16 kA 1 s |
| Short-circuit rating | 20 kA |
| Metering | Multifunction meter, CT operated |
| Ventilation | Natural louvresmade to order: Forced fan |
| Oil containment | Integrated sump |