by Thanjavurprakash Transformer Works (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Thanjavurprakash Transformer Works (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

Thanjavurprakash Volt station auxiliary transformer, offered in 6 rating options from 50 kVA to 1600 kVA. Key features: limits fault current to relay-set value, low zero-sequence impedance and short-time rated for fault duty. Used by solar plant 33 kV systems, substation auxiliary supply and industrial networks. Designed and tested to IS 1180, IS 2026 and IEC 60076. Lead time 3-5 weeks; delivers to All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Thanjavurprakash
Model
THA-2C6 series
Listing type
Product
Unit
nos
Minimum order
1 nos
Lead time
3-5 weeks
Warranty
18 months
Standards
IS 1180, IS 2026, IEC 60076
Delivers to
All India
GST rate
18 %
Country of origin
India
Packaging
Steel skid with shrink wrap
Delivery terms
Door delivery in metro cities
Returns
Replacement of items damaged in transit within 7 days
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Rating50 kVATHA-2C6-01Rating: 50 kVA1 nos · 3-5 weeksfor verified buyers
Rating100 kVATHA-2C6-02Rating: 100 kVA1 nos · 3-5 weeksfor verified buyers
Rating315 kVATHA-2C6-03Rating: 315 kVA1 nos · 3-5 weeksfor verified buyers
Rating630 kVATHA-2C6-04Rating: 630 kVA1 nos · 3-5 weeksfor verified buyers
Rating1000 kVATHA-2C6-05Rating: 1000 kVA1 nos · 8-10 weeksfor verified buyers
Rating1600 kVATHA-2C6-06Rating: 1600 kVA1 nos · 8-10 weeksfor verified buyers

Specifications

Rating50 kVA to 1600 kVA (see variants)
TypeStation servicemade to order: Earthing (zig-zag) / Auxiliary (Dyn11)
Primary voltage11 kVmade to order: 33 kV / 132 kV
Secondary voltage0.433 kVmade to order: 3.3 kV
Short-time rating30 smade to order: 10 s
Neutral current200 Amade to order: 400 A / 800 A
CoolingDry AN
Vector groupDyn11
Impedance4%made to order: 5% / Low zero-sequence
Tap changerOff-circuit +/- 5%
TerminationCable box
MountingSkidmade to order: Plinth
Neutral protectionCT on neutral