Online double-conversion UPS, Eco seriesSample
by Tirhuttamra Battery Systems (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Tirhuttamra Battery Systems (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
The Eco range of online double-conversion UPS by Tirhuttamra covers 6 rating options (1 kVA to 60 kVA). Key features: hot-swappable power modules, low input current THD and LCD display with event log. Typically used for data centres, banking and IT offices and industrial process loads. Designed and tested to IEC 62040-1, IEC 62040-3 and IS 16242. Lead time 4-6 weeks; delivers to All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Tirhuttamra
- Model
- TIR-D67 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 5 nos
- Lead time
- 4-6 weeks
- Warranty
- 12 months
- Standards
- IEC 62040-1, IEC 62040-3, IS 16242
- Delivers to
- All India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- As per item, transit-safe
- Delivery terms
- FOR nearest railhead
- Returns
- No returns on made-to-order items
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Rating1 kVATIR-D67-01 | Rating: 1 kVA | 5 nos · 4-6 weeks | for verified buyers |
| Rating3 kVATIR-D67-02 | Rating: 3 kVA | 5 nos · 4-6 weeks | for verified buyers |
| Rating10 kVATIR-D67-03 | Rating: 10 kVA | 5 nos · 4-6 weeks | for verified buyers |
| Rating20 kVATIR-D67-04 | Rating: 20 kVA | 5 nos · 4-6 weeks | for verified buyers |
| Rating40 kVATIR-D67-05 | Rating: 40 kVA | 5 nos · 4-6 weeks | for verified buyers |
| Rating60 kVATIR-D67-06 | Rating: 60 kVA | 5 nos · 4-6 weeks | for verified buyers |
Specifications
| Rating | 1 kVA to 60 kVA (see variants) |
|---|---|
| Topology | Online double conversion |
| Input / output | 3-ph / 1-phmade to order: 1-ph / 1-ph / 3-ph / 3-ph |
| Input voltage window | 304-478 V |
| Output power factor | 0.9made to order: 0.8 / 1.0 |
| Efficiency (online) | 95% |
| Rectifier type | IGBT PFCmade to order: 6-pulse SCR / 12-pulse SCR |
| DC bus voltage | 384 V |
| Battery type | Tubularmade to order: VRLA / Li-ion |
| Backup time | 60 minmade to order: 10 min / 30 min |
| Overload | 125% for 10 minmade to order: 150% for 1 min |
| Bypass | Static and manual maintenance bypass |
| Communication | RS485, SNMP, dry contacts |