Catalogue / Substation & line O&M
Battery bank and DC system maintenance, Prime 2 seriesSample
by Trishulcore Projects (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Trishulcore Projects (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
The Prime 2 service of battery bank and DC system maintenance by Trishulcore covers 3 voltage level options (132 kV to 400 kV). Highlights: fault analysis within 24 hours, licensed supervisory staff and oil leak and silica gel checks. Used by industrial captive substations, state utility outsourcing and renewable pooling substations. Delivered in line with CEA (Measures relating to Safety) Regulations, CEA (Grid Standards) Regulations and IS 10028 (Transformer Installation). Mobilisation Baseline condition audit first; serves East & North-East India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Trishulcore
- Model
- TRI-CB2 series
- Listing type
- Service
- Unit
- month
- Minimum order
- 1 month
- Lead time
- Baseline condition audit first
- Warranty
- Service credits for avoidable outages
- Standards
- CEA (Measures relating to Safety) Regulations, CEA (Grid Standards) Regulations, IS 10028 (Transformer Installation)
- Delivers to
- East & North-East India
- GST rate
- 18 %
- Country of origin
- India
- Delivery terms
- Site mobilisation as per work order
- Returns
- Re-work of defective scope at no cost
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Voltage level132 kVTRI-CB2-01 | Voltage level: 132 kV | 1 month · Baseline condition audit first | for verified buyers |
| Voltage level220 kVTRI-CB2-02 | Voltage level: 220 kV | 1 month · Baseline condition audit first | for verified buyers |
| Voltage level400 kVTRI-CB2-03 | Voltage level: 400 kV | 1 month · Baseline condition audit first | for verified buyers |
Specifications
| Voltage level | 132 kV to 400 kV (see variants) |
|---|---|
| Scope | Operation, maintenance and statutory compliance |
| Shift pattern | 3 shifts, 24x7made to order: General shift plus on-call |
| Manpower | Two engineers plus 12 staffmade to order: Engineer plus 6 operators |
| Line patrolling | Monthly foot patrol |
| Testing | Thermography twice a yearmade to order: Annual relay and CT/PT test |
| Statutory records | CEIG renewal supportmade to order: Log books, permits, shutdown register |
| Spares | Critical spares by owner |
| Response time | 4 hoursmade to order: 2 hours for trip |
| Reporting | Monthly fault and maintenance report |
| Term | 1 year |