Catalogue / Thermography & condition monitoring
Online partial discharge and UV corona inspection, Flex seriesSample
by Trishulcore Projects (Sample) · verified by BARREL
Price on quote
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Trishulcore Projects (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
The Flex service of online partial discharge and UV corona inspection by Trishulcore covers 5 asset size options (1 MW to 50 MW). Highlights: load condition recorded with each scan, trend data for repeated surveys and safe scanning without shutdown. Typically used for wind turbine electrical systems, substation switchgear and transformers and industrial MCC panels. Delivered in line with ISO 18434-1, IEC 62446-3 and IEEE 1584. Mobilisation Mobilisation in 3-7 days; serves East & North-East India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Trishulcore
- Model
- TRI-B26 series
- Listing type
- Service
- Unit
- site
- Minimum order
- 1 site
- Lead time
- Mobilisation in 3-7 days
- Warranty
- Report accuracy as per method
- Standards
- ISO 18434-1, IEC 62446-3, IEEE 1584
- Delivers to
- East & North-East India
- GST rate
- 18 %
- Country of origin
- India
- Delivery terms
- Site mobilisation as per work order
- Returns
- Re-work of defective scope at no cost
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Asset size1 MWTRI-B26-01 | Asset size: 1 MW | 1 site · Mobilisation in 3-7 days | on quote |
| Asset size5 MWTRI-B26-02 | Asset size: 5 MW | 1 site · Mobilisation in 3-7 days | on quote |
| Asset size10 MWTRI-B26-03 | Asset size: 10 MW | 1 site · Mobilisation in 3-7 days | on quote |
| Asset size25 MWTRI-B26-04 | Asset size: 25 MW | 1 site · Report in 5-10 days | on quote |
| Asset size50 MWTRI-B26-05 | Asset size: 50 MW | 1 site · Report in 5-10 days | on quote |
Specifications
| Asset size | 1 MW to 50 MW (see variants) |
|---|---|
| Technique | Drone thermal imaging |
| Camera resolution | 640x480 radiometric |
| Deliverable | CAT-wise severity ranking with fix actionsmade to order: Annotated hotspot report |
| Drone services | Ground sampling 3 cm per pixelmade to order: Orthomosaic of full plant |
| Defect classification | Delta T based severity |
| Team | Level II thermographer |
| Certification | ISO 18436-7 trained |
| Turnaround | Report in 10 days |
| Frequency | Annual or bi-annual planmade to order: One-time |
| Software | Cloud dashboard with trend history |