Catalogue / Transformer overhaul & oil filtration

No photo yet

DGA based diagnostics and reclamation, Smart 5 seriesSample

by Trishulmark Projects (Sample) · verified by BARREL

Price on quote

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Trishulmark Projects (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

The Smart 5 service of DGA based diagnostics and reclamation by Trishulmark covers 4 transformer rating options (1 MVA to 20 MVA). Design: nitrogen or dry air purge on opening, core insulation resistance checks and oil sampling and DGA before work. Typically used for state utility asset life extension, industrial distribution transformers and captive power plants. Delivered in line with IS 335 (Mineral Insulating Oil), IS 1866 (Oil Maintenance) and IEC 60422. Mobilisation Mobilisation in 3-5 days; serves All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Trishulmark
Model
TRI-C07 series
Listing type
Service
Unit
nos
Minimum order
1 nos
Lead time
Mobilisation in 3-5 days
Warranty
Oil quality guarantee 6 months
Standards
IS 335 (Mineral Insulating Oil), IS 1866 (Oil Maintenance), IEC 60422
Delivers to
All India
GST rate
18 %
Country of origin
India
Delivery terms
Site mobilisation as per work order
Returns
Re-work of defective scope at no cost
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Transformer rating1 MVATRI-C07-01Transformer rating: 1 MVA1 nos · Mobilisation in 3-5 dayson quote
Transformer rating5 MVATRI-C07-02Transformer rating: 5 MVA1 nos · Mobilisation in 3-5 dayson quote
Transformer rating10 MVATRI-C07-03Transformer rating: 10 MVA1 nos · Planned shutdown requiredon quote
Transformer rating20 MVATRI-C07-04Transformer rating: 20 MVA1 nos · Planned shutdown requiredon quote

Specifications

Transformer rating1 MVA to 20 MVA (see variants)
ServiceOil reclamationmade to order: Oil filtration and dehydration / Internal inspection and overhaul / Full overhaul with rewinding
Filtration machineMobile 12000 L/hrmade to order: Vacuum dehydration 6000 L/hr
Oil BDV targetAbove 70 kV
Moisture targetBelow 10 ppm
TestingFull routine tests after overhaulmade to order: DGA, furan, BDV, tan delta
SparesGaskets and silica gelmade to order: Bushings and OLTC parts at cost
Downtime3-4 weeks
Site workWorkshop repair
CrewSpecialised overhaul teammade to order: 4 technicians with supervisor
CertificateOil test report from NABL lab

BARREL: Bharat Atom Renewable Resources Energy Limited