Catalogue / Gas & water analysers
Multi-gas continuous emission analyser, Ultra seriesSample
by Trishultron Controls (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Trishultron Controls (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Trishultron Ultra multi-gas continuous emission analyser, offered in 4 parameter options from Dissolved oxygen to Flue gas O2. Highlights: online continuous measurement with alarm relays, automatic calibration and cleaning option and sample conditioning panel supplied. Suited to cooling water treatment, boiler water and steam cycle chemistry and stack emission monitoring. Designed and tested to IEC 61207, IS 3025 and IEC 60079-0. Lead time 3-5 weeks; delivers to All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Trishultron
- Model
- TRI-BC3 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 1 nos
- Lead time
- 3-5 weeks
- Warranty
- 12 months from commissioning
- Standards
- IEC 61207, IS 3025, IEC 60079-0
- Delivers to
- All India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Corrugated box on pallet
- Delivery terms
- FOR nearest railhead
- Returns
- Returns within 15 days if unused, in original packing
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| ParameterDissolved oxygenTRI-BC3-01 | Parameter: Dissolved oxygen | 1 nos · 3-5 weeks | for verified buyers |
| ParameterTurbidityTRI-BC3-02 | Parameter: Turbidity | 1 nos · 3-5 weeks | for verified buyers |
| ParameterSilicaTRI-BC3-03 | Parameter: Silica | 1 nos · 8-12 weeks | for verified buyers |
| ParameterFlue gas O2TRI-BC3-04 | Parameter: Flue gas O2 | 1 nos · 8-12 weeks | for verified buyers |
Specifications
| Parameter | Dissolved oxygen to Flue gas O2 (see variants) |
|---|---|
| Measurement range | 0-2000 µS/cmmade to order: pH 0-14 / 0-20 mg/L / 0-1000 NTU |
| Accuracy | ±1% of reading |
| Output | Relay alarm |
| Sample flow | 100-500 mL/min |
| Power supply | 24 VDC |
| Enclosure | IP65 |
| Calibration | Two-point manual |
| Sensor life | 12-24 months |
| Response time | < 30 s |
| Hazardous area | Non-hazardousmade to order: Ex d |
| Display | Graphic colour LCD |