Catalogue / Substation & line O&M
Substation O&M with 24x7 shift operation, Eco seriesSample
by Tungabhadra Engineering Services (Sample) · verified by BARREL
Price on quote
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Tungabhadra Engineering Services (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Substation O&M with 24x7 shift operation from Tungabhadra, Eco series: 3 voltage level options between 11 kV and 66 kV. Key features: oil leak and silica gel checks, insulator and joint inspection and permit-to-work and lockout-tagout. Used by state utility outsourcing, railway and metro sub-stations and industrial captive substations. Delivered in line with CEA (Measures relating to Safety) Regulations, CEA (Grid Standards) Regulations and IS 10028 (Transformer Installation). Mobilisation Baseline condition audit first; serves East & North-East India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Tungabhadra
- Model
- TUN-0A7 series
- Listing type
- Service
- Unit
- month
- Minimum order
- 1 month
- Lead time
- Baseline condition audit first
- Warranty
- As per contract
- Standards
- CEA (Measures relating to Safety) Regulations, CEA (Grid Standards) Regulations, IS 10028 (Transformer Installation)
- Delivers to
- East & North-East India
- GST rate
- 18 %
- Country of origin
- India
- Delivery terms
- Site mobilisation as per work order
- Returns
- Re-work of defective scope at no cost
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Voltage level11 kVTUN-0A7-01 | Voltage level: 11 kV | 1 month · Baseline condition audit first | on quote |
| Voltage level33 kVTUN-0A7-02 | Voltage level: 33 kV | 1 month · Baseline condition audit first | on quote |
| Voltage level66 kVTUN-0A7-03 | Voltage level: 66 kV | 1 month · Baseline condition audit first | on quote |
Specifications
| Voltage level | 11 kV to 66 kV (see variants) |
|---|---|
| Scope | Maintenance onlymade to order: Operation and maintenance / Operation, maintenance and statutory compliance |
| Shift pattern | General shift plus on-callmade to order: 3 shifts, 24x7 |
| Manpower | Engineer plus 6 operatorsmade to order: Two engineers plus 12 staff |
| Line patrolling | Quarterly drone patrol |
| Testing | Annual relay and CT/PT test |
| Statutory records | CEIG renewal support |
| Spares | Critical spares by owner |
| Response time | 4 hours |
| Reporting | Monthly fault and maintenance reportmade to order: Real-time dashboards |
| Term | 3 years |