Catalogue / Thermography & condition monitoring
Online partial discharge and UV corona inspection, Neo seriesSample
by Tungabhadra Engineering Services (Sample) · verified by BARREL
Price on quote
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Tungabhadra Engineering Services (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
The Neo service of online partial discharge and UV corona inspection by Tungabhadra covers 4 asset size options (1 MW to 25 MW). Design: safe scanning without shutdown, hotspot location tagged with GPS and priority list of defects with repair advice. Suited to substation switchgear and transformers, wind turbine electrical systems and solar plants (module and string hotspots). Delivered in line with ISO 18434-1, IEC 62446-3 and IEEE 1584. Mobilisation Mobilisation in 3-7 days; serves East & North-East India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Tungabhadra
- Model
- TUN-B24 series
- Listing type
- Service
- Unit
- site
- Minimum order
- 1 site
- Lead time
- Mobilisation in 3-7 days
- Warranty
- Re-scan of repaired points at no cost
- Standards
- ISO 18434-1, IEC 62446-3, IEEE 1584
- Delivers to
- East & North-East India
- GST rate
- 18 %
- Country of origin
- India
- Delivery terms
- Site mobilisation as per work order
- Returns
- Re-work of defective scope at no cost
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Asset size1 MWTUN-B24-01 | Asset size: 1 MW | 1 site · Mobilisation in 3-7 days | on quote |
| Asset size5 MWTUN-B24-02 | Asset size: 5 MW | 1 site · Mobilisation in 3-7 days | on quote |
| Asset size10 MWTUN-B24-03 | Asset size: 10 MW | 1 site · Report in 5-10 days | on quote |
| Asset size25 MWTUN-B24-04 | Asset size: 25 MW | 1 site · Report in 5-10 days | on quote |
Specifications
| Asset size | 1 MW to 25 MW (see variants) |
|---|---|
| Technique | Vibration analysis |
| Camera resolution | 1280x1024 radiometricmade to order: 640x480 radiometric |
| Deliverable | CAT-wise severity ranking with fix actionsmade to order: Annotated hotspot report |
| Drone services | Orthomosaic of full plantmade to order: Ground sampling 3 cm per pixel |
| Defect classification | Delta T based severity |
| Team | Level II thermographer plus pilot |
| Certification | ISO 18436-7 trainedmade to order: Technicians with ASNT level II |
| Turnaround | Report in 10 days |
| Frequency | Annual or bi-annual planmade to order: One-time |
| Software | Cloud dashboard with trend historymade to order: Analyser software with thermal library |