Catalogue / Thermography & condition monitoring
Drone thermal inspection of solar plants, Duo 2 seriesSample
by Tungabhadra Engineering Services (Sample) · verified by BARREL
Price on quote
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Tungabhadra Engineering Services (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
The Duo 2 service of drone thermal inspection of solar plants by Tungabhadra covers 4 asset size options (1 MW to 25 MW). Highlights: trend data for repeated surveys, hotspot location tagged with GPS and re-scan after repair included. Used by substation switchgear and transformers, solar plants (module and string hotspots) and industrial MCC panels. Delivered in line with ISO 18434-1, IEC 62446-3 and IEEE 1584. Mobilisation Report in 5-10 days; serves East & North-East India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Tungabhadra
- Model
- TUN-F93 series
- Listing type
- Service
- Unit
- site
- Minimum order
- 1 site
- Lead time
- Report in 5-10 days
- Warranty
- Report accuracy as per method
- Standards
- ISO 18434-1, IEC 62446-3, IEEE 1584
- Delivers to
- East & North-East India
- GST rate
- 18 %
- Country of origin
- India
- Delivery terms
- Site mobilisation as per work order
- Returns
- Re-work of defective scope at no cost
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Asset size1 MWTUN-F93-01 | Asset size: 1 MW | 1 site · Report in 5-10 days | on quote |
| Asset size5 MWTUN-F93-02 | Asset size: 5 MW | 1 site · Report in 5-10 days | on quote |
| Asset size10 MWTUN-F93-03 | Asset size: 10 MW | 1 site · Report in 5-10 days | on quote |
| Asset size25 MWTUN-F93-04 | Asset size: 25 MW | 1 site · Report in 5-10 days | on quote |
Specifications
| Asset size | 1 MW to 25 MW (see variants) |
|---|---|
| Technique | Partial discharge testing |
| Camera resolution | 640x480 radiometric |
| Deliverable | CAT-wise severity ranking with fix actions |
| Drone services | Orthomosaic of full plant |
| Defect classification | Delta T based severity |
| Team | Level II thermographer plus pilotmade to order: Level II thermographer |
| Certification | Technicians with ASNT level II |
| Turnaround | Report in 10 days |
| Frequency | Annual or bi-annual planmade to order: One-time |
| Software | Cloud dashboard with trend history |